With the depletion of fossil fuel, the world is shifting towards the sources of alternate energy, but a major impediment in their utilization is their inter-connection with the grid. This paper builds on the model of a grid-connected converter which is used to interface the different alternate energy sources using matlab/simulink as simulation software. The classical control techniques proportional/proportional integral (P/PI) are applied on the model of the two-level grid-connected converter with LCL filter. The overall structure of the system is based upon the inner-loop capacitor current and outerloop controller feedback. These parameters are varied and their effect is investigated in the presence of utility harmonics. The limitations and performance of the system with the variation in gain values is studied so that optimal gains can be identified.

Keywords

Grid-Connected Converters, Micro-grid, Total Harmonic Distortion