Hashemi, Mohamadreza
- Improvement in the Synchronization Process of the Voltage-Sourced Converters Connected to the Grid by PLL in Order to Detect and Block the Double Frequency Disturbance Term
Abstract Views :554 |
PDF Views:0
Authors
Source
Indian Journal of Science and Technology, Vol 6, No 7 (2013), Pagination: 4940-4952Abstract
Phase-Locked Loop (PLL) Structures have many applications in power system engineering. When required the synchronous performance of Voltage Sourced Converter (VSC) with Grid, such as wind power generation system, active filters, HVDC transmission lines and FACTS devices, the most common method for accurate estimation of frequency of network, is to use a PLL. However, problems such as grid disturbances due to noise, voltage unbalances, lack of coordination, changes in grid frequency and harmonics can produce a frequency disturbance, twice the grid frequency and disturbed PLL and also the control system connected to it. In this paper, common structures of PLL is introduced. After that, unbalance and disturbance in the three phase input of PLL is studied. Then for idea and invention in PLL, a new control method based on predictive control technique is used in the control strategy of converter. Furthermore, the use of type III controller in PLL to ensure optimal performance in various conditions is proposed in this paper. How to set the parameters of the proposed controller is described by the Bode stability criterion. Conducting simulations to evaluate the performance of the proposed method is done in PSIM software. According to the proposed method and the result observed, the double frequency disturbance term is weakened and also the transient state is improved.Keywords
Phase-Locked Loop (PLL), Voltage-Sourced Converters (VSC), Synchronization, Current Control, Unbalanced VoltageReferences
- Yazdani A, and Iravani R (2010). Voltage-sourced Converters in Power Systems. Modeling, Control, and Applications, Chapters 3, 8, Wiley/IEEE Press.
- Teodorescu R, Liserre M et al. (2011). Grid Converters for Photovoltaic and Wind Power Systems, Chapters 4, 8, Wiley/IEEE Press.
- Paice D A (1999). Power Electronic Converter Harmonics: Multipulse Methods for Clean Power, Chapters 1, 2, Wiley/IEEE Press.
- Guo X-Q, Wu W-Y et al. (2011). Phase locked loop and synchronization methods for grid-interfaced converters: a Review , Przegląd Elektrotechniczny, vol 87(4),182–187.
- Blaabjerg F, Teodorescu R et al. (2006). Overview of control and grid synchronization for distributed power generation systems, IEEE Transactions on Industrial Electronics, vol 53(5), 1398–1409.
- Golestan S, Monfared M et al. (2012). Design and tuning of a modified power-based PLL for single-phase grid-connected power conditioning system, IEEE Transactions on Power Electronics, vol 27(8), 3639–3650.
- Golestan S, Monfared M et al. (2013). Design oriented study of advanced synchronous reference frame phase-locked loops, IEEE Transactions on Power Electronics, vol 28(2), 765–778.
- Golestan S, Monfared M et al. (2013). Dynamic assessment of advanced single-phase PLL structures, IEEE Transactions on Industrial Electronics, vol 60(6), 2167–2177.
- Golestan S, and Monfared M (2013). Advantages and challenges of a type-3 PLL, IEEE Transactions on Power Electronics, vol 28(11), 4985–4997.
- Fernandez F D F (2009). Contributions to grid-synchronization techniques for power electronic converters, Ph.D. Thesis.
- Ciobotaru M (2009). Reliable grid condition detection and control of single-phase distributed power generation systems, PhD Thesis.
- Timbus A (2007). Grid monitoring and advanced control of distributed power generation systems, PhD Thesis.
- Timbus A V, Teodorescu R et al. (2006). Linear and nonlinear control of distributed power generation systems, 41st IAS Annual Meeting Conference Record of the 2006 IEEE Industry Applications Conference, 2006, vol 2, 1015–1023.
- Yazdani D (2009). A new power signal processor for converter-interfaced distributed generation systems, PhD Thesis.
- Comanescu M, and Xu L (2006). An improved flux observer based on pll frequency estimator for sensorless vector control of induction motors, IEEE Transactions on Industrial Electronics, vol 53, No. 1, 50–56.
- Cataliotti A, Cosentino V et al. (2007). A phase-locked loop for the synchronization of power quality instruments in the presence of stationary and transient disturbances, IEEE Transactions on Instrumentation and Measurement, vol 56, No. 6, 2232–2239.
- Carvalho J R, Gomes P H et al. (2007). PLL based multirate harmonic estimation, IEEE Conference, 1–6.
- Mojiri M, Karimi-Ghartemani M et al. (2007). Estimation of power system frequency using an adaptive notch filter, IEEE Transactions on Instrumentation and Measurement, vol 56, No. 6, 2470–2477.
- Karimi-Ghartemani M (2006). A novel three-phase magnitude-phase-locked loop system, IEEE Transactions on Circuits and Systems—I: Regular Papers, vol 53, No. 8, 1792–1802.
- Karimi-Ghartemani M, and Karimi H (2007). Processing of symmetrical components in time-domain, IEEE Transactions on Power Systems, vol 22(2), 572–579.
- A New Method for Islanding Detection the Grid Connected Inverters in Case of Unbalanced Loads
Abstract Views :561 |
PDF Views:0
Authors
Affiliations
1 Department of Electrical Engineering, Science and Research Branch, Islamic Azad University, Arak, IR
2 Department of Electrical Engineering, Faculty of Engineering, Arak University, Arak, IR
1 Department of Electrical Engineering, Science and Research Branch, Islamic Azad University, Arak, IR
2 Department of Electrical Engineering, Faculty of Engineering, Arak University, Arak, IR
Source
Indian Journal of Science and Technology, Vol 6, No 8 (2013), Pagination: 5024-5035Abstract
One of the facing problems in distributed generation is being unintentionally islanded which the detection of this phenomenon is of great importance. Common methods are active and passive islanding detection. These two methods are based on changing in parameters such as frequency, voltage and current harmonics. If, after the islanding occur, this changes are revealing and visible, islanding phenomenon is demonstrated which is detected by passive methods. If the generated power of inverter is equal to local loads consumption and assuming of the generated reactive power of grid connected inverter equal to zero, it should be detected by active methods but these two methods have some challenges such as reduction in power quality or wide Non Detection Zone (NDZ). In this paper, in proposed method, change of a new parameter will be studied for islanding detection diagnosis. With the difference that the studied system is a three phase system and unbalanced load is studied which is more consistent to reality. Because of small changes in parameters, we have to find the right approach toward active methods. Generally there are two views about the islanding performance. At first view, this phenomenon is seems negatively but in fact this is an opportunity. The first view suggests that all generators in the island should bring out of grid within a maximum of two seconds. In this view the concept of anti-islanding protection is proposed to tackle the task of creating such islands. The second view expresses the concept of micro grid. In this case as far as possible, power required by Inner Island loads were provided by distributed generators. The studied system was similar to standard IEEE-1547 and UL-1741. With the difference that we used three phase and local loads are assumed unbalanced. Conventional active detection methods are not able to identify the island with the aim to help keep it stable. They usually try to bring out the electrical parameters such as voltage and frequency from nominal limits. So in micro grids the island should be diagnosed using passive or remote techniques. Note that detection time of 2 seconds which is referred to on standards is not good and the detection time must be lower than this value. However, the proposed method that is one of the active detection methods is capable for use in micro grids. Simulation results using PSIM software on standard network shows the effectiveness of the proposed method.Keywords
Islanding, Unbalanced Loads, dq-frame, Phase Locked Loop (PLL), Non Detection Zone (NDZ), Micro-gridReferences
- Yazdani A, and Iravani R (2010). Voltage-sourced converters in power systems, Modeling, Control, and Applications Chapter 3, 8, Wiley/IEEE Press.
- Teodorescu R, Liserre M et al. (2011). Grid converters for photovoltaic and wind power systems, Chapter 5, Wiley/IEEE Press.
- Velasco D, Trujillo C et al. (2010). An active anti-islanding method based on phase-PLL perturbation, IEEE Transactions on Power Electronics, vol 26(4), 1056–1066.
- Lee J, Min B et al. (2011). Active frequency with a positive feedback anti-islanding method based on a Robust PLL algorithm for grid-connected PV PCS, Journal of Power Electronics, vol 11, No. 3, 360–368.
- Chung I, and Moon S (2007). A new islanding detection method using phase-locked loop for inverter-interfaced distributed generators, Journal of Electrical Engineering & Technology, vol 2, No. 2, pp. 165–171.
- Mahdian H, Hashemi M et al. (2013). Improvement in the synchronization process of the voltage-sourced converters connected to the Grid by PLL in order to Detect and Block the Double Frequency Disturbance Term, Indian Journal of Science and Technology, Vol 6 (7), July 2013.
- Chung I, and Moon S (2007). A new islanding detection method using phase-locked loop for inverter-interfaced distributed generators, Journal of Electrical Engineering & Technology, vol 2, No. 2, 165–171.
- Lee J, Min B et al. (2011). Active frequency with a positive feedback anti-islanding method based on a robust PLL algorithm for grid-connected PV PCS, Journal of Power Electronics, vol 11(3), 360–368.
- Velasco D, Trujillo C L et al. (2010). An active Anti-islanding method based on phase-PLL perturbation, IEEE conference, vol 26(4), 1056–1066.
- Yu B, Matsui M et al. (2010). A review of current anti-islanding methods for photovoltaic power system, Solar energy transaction, vol 84(5), 745–754.
- Trujillo C L, Velasco D et al. (2010). Analysis of active islanding detection methods for grid-connected microinverters for renewable energy processing, Applied Energy, vol 87(11), 3591–3605.
- Rani B I, Srikanth M et al. (2013). An active islanding detection technique for current controlled inverter, Renewable Energy, vol 51, 189–196.
- Hashemi F, Kazemi A et al. (2012). A new algorithm to detection of anti-islanding based on dqo transform, Energy Procedia, vol 14, 81–86.
- Wrinch M C. Negative Sequence Impedance Measurement for Distributed Generator Islanding Detection, PhD Thesis, 1–6.
- Bahrani B. Islanding detection and control of islanded single and two-parallel distributed generation units, MSC Thesis.