Open Access Open Access  Restricted Access Subscription Access

Groundwater Responses to Artificial Recharge of Rainwater in Chennai, India: a Case Study in an Educational Institution Campus


Affiliations
1 St. Peters Engineering College, Avadi, Chennai- 600054, India
2 Centre for Water Resources, Anna Univ.-Chennai, Chennai 600025
 

This paper reports the response of the groundwater in the St Peter's Engineering College campus, Avadi, near Chennai, India. Artificial recharge of rainwater was done through roof top harvesting methods during 2004 to 2007. Based on a hydro geological survey of the campus, eleven bore well were sunk for augmenting water supply to the campus. The lithology of each bore well was also recorded. A percolation pond in 1 ha area on the south eastern side of the campus was dug to collect and store the rainwater harvested from rooftops of the campus buildings. The survey also assisted in the identification and location of about 70 number of recharge wells in the campus. Pumping test was conducted in well no:3 to assess the hydraulic conductivity and calculate other aquifer parameters during 2005. A three layer hydro geological model of the aquifer was applied in Visual Modflow ver 4.1 environment and the model fit was 84% between observed and predicted values (R2 = 0.844). Significant increase in water level in the top aquifer during 2007 was recorded when compared to 2004. The flow profiles in the middle and deep aquifer showed responses, through changes in the direction of flow to the pumping wells (5, 6 in 2004 and 2, 3 in 2007). In 2007, with improved recharge, changes in the direction of groundwater flow and discharge of water from the aquifer in the southern part of the campus can be noticed. The flow directions in the three aquifer layers also indicated that the northern part of the study area serves as an effective recharge zone for the St Peter's Engineering College Campus. Rainwater harvesting and recharge studies form important part in groundwater restoration and management in intensely urbanized cities/townships.

Keywords

Rainwater Harvesting Methods, Aquifer Recharge, Groundwater Flow, Aquifer Test Pro, Visual Modflow
User

  • Abdul Azeez S, Al Turbak and Fouad F. Al-Muttair (1989) Evaluation of dams as a recharge method. J. Water Res. Devpt. 5, 119-124.
  • Abiko Hiroto (1999) Artificial recharge of ground water in Yamagata city, Japan. J. Ground Water Technol. 41, 19 -26.
  • Amitha Kommadath (2000) Estimation of natural ground water. J. Mech. Working Technol., Lake 2000 Section 7 Online. http://ces.iisc.ernet.in/energy/water/proceed/section7/paper5/section7paper5.htm. Extracted on Jan.2010.
  • CGWB (2007) Manual on artificial recharge of ground water. Central Ground Water Board, Ministry of Water Resources, Govt. of India, New Delhi.
  • David CA (1998) Guidance on the use of rain water tanks. Natl. Environ. Health Forum Monographs, Water series no.3, Australia.
  • Dharmesh Mashru (2006) Suggested design approach for planning and designing recharge wells and systems. Natl. Seminar on Rain Water Harvesting & Water Management. pp: 365-370.
  • Giovani Pietro Beretta, Monica Avanzina and Adelio Pagottao (2004) Managing groundwater rise: Experimental results and modeling of water pumping from a quarry lake in Milan urban area (Italy). J. Environ. Geol. 45, 600-608.
  • John Stiefel, Assefa Melesse, Michael McClain, Rene Price, Elizabeth Anderson and Narendra Chauhan (2009) Effects of rain water- harvesting-induced artificial recharge on the groundwater of wells in Rajasthan, India. Hydrogeology. J. 17, 2061-2073.
  • Khepar SD, Yadav AK, Sondhi SK and Arpan Sherring (2000) Modelling surplus canal water releases for artificial recharge of groundwater through surface drainage system. J. Irrigation Sci. 19, 95-100.
  • Kumar CP and Seethapathi PV (2002) Assessment of natural groundwater recharge in Upper Ganga Canal command area. J. Appl. Hydrol. XV, 13-20.
  • Ministry of Water Resources, Govt. of India (2010) Water availability. http://wrmin.nic.in/index1.asp? linkid=189&langid=1. Extracted on Jan 2010.
  • Mohanakrishnan A (1990) Preparatory effort for different water use in irrigate agriculture. In: Irrigation Publication. Irrigation Management Training Institute, Tiruchirappalli. pp:73-81.
  • Ramaswamy Sakthivadivel (2002) Groundwater recharge movement in India. http://www.iwmi.cgiar.org.
  • Rees D (2000) Partially below ground (PBG) tanks for rainwater storage instructions for manufacture. DTU Technical Release Series TR-RWH01, Univ. of Warwick UK.
  • Rees D and Whitehead V (2000) Ferro-cement jar instructions for manufacture. DTU Technical Release Series TR-RWH06, Univ. of Warwick UK.
  • Saravi MM, Malekian A and Nouri B (2006) Identification of suitable sites for groundwater recharge. Intl. Conf. on Water Resources & Arid Environment. Nov. 26-29.
  • Singh B (1958) Water resources of India. J. Indian Water Works Asso. XXX (4), 229-233.

Abstract Views: 655

PDF Views: 117




  • Groundwater Responses to Artificial Recharge of Rainwater in Chennai, India: a Case Study in an Educational Institution Campus

Abstract Views: 655  |  PDF Views: 117

Authors

V. B. M. Sayana
St. Peters Engineering College, Avadi, Chennai- 600054, India
E. Arunbabu
Centre for Water Resources, Anna Univ.-Chennai, Chennai 600025
S. Ravichandran
Centre for Water Resources, Anna Univ.-Chennai, Chennai 600025
K. Karunakaran
Centre for Water Resources, Anna Univ.-Chennai, Chennai 600025

Abstract


This paper reports the response of the groundwater in the St Peter's Engineering College campus, Avadi, near Chennai, India. Artificial recharge of rainwater was done through roof top harvesting methods during 2004 to 2007. Based on a hydro geological survey of the campus, eleven bore well were sunk for augmenting water supply to the campus. The lithology of each bore well was also recorded. A percolation pond in 1 ha area on the south eastern side of the campus was dug to collect and store the rainwater harvested from rooftops of the campus buildings. The survey also assisted in the identification and location of about 70 number of recharge wells in the campus. Pumping test was conducted in well no:3 to assess the hydraulic conductivity and calculate other aquifer parameters during 2005. A three layer hydro geological model of the aquifer was applied in Visual Modflow ver 4.1 environment and the model fit was 84% between observed and predicted values (R2 = 0.844). Significant increase in water level in the top aquifer during 2007 was recorded when compared to 2004. The flow profiles in the middle and deep aquifer showed responses, through changes in the direction of flow to the pumping wells (5, 6 in 2004 and 2, 3 in 2007). In 2007, with improved recharge, changes in the direction of groundwater flow and discharge of water from the aquifer in the southern part of the campus can be noticed. The flow directions in the three aquifer layers also indicated that the northern part of the study area serves as an effective recharge zone for the St Peter's Engineering College Campus. Rainwater harvesting and recharge studies form important part in groundwater restoration and management in intensely urbanized cities/townships.

Keywords


Rainwater Harvesting Methods, Aquifer Recharge, Groundwater Flow, Aquifer Test Pro, Visual Modflow

References





DOI: https://doi.org/10.17485/ijst%2F2010%2Fv3i2%2F29663