In present day’s security from unauthorized humans (intruders) and fire/flame is one of the essential concerns especially in industries, banks, airports, railway stations and other restricted areas. Therefore, we introduce an Electronic Security System (ESS). The ESS provides the attentive message from flame as well as intruders. The proposed system generally consists of 3 devices namely PIR sensors, MSP430 and GSM. The flames and intruder are recognized by PIR. These activities are feeding to HMM, which are synthesized by wavelet transform. When there is an action occurs within the sensor range, then signal from sensor is processed by biorthogonal wavelet transform and then feeding to HMMs. The detection of intruder and flame is updated according to the HMM producing the highest probability. After that the alert message is sent to authorize person using GSM.
User

  • Sathishkumar M, Rajini S. Smart surveillance system using PIR sensor network and GSM. International Journal of Advanced Research in Computer Engineering and Technology (IJARCET). 2015 Jan; 4(1).
  • Erden F, Toreyin BU, Soyer EB, Inac I, Gunay O, Kose K, Cetin AE. Wavelet based flickering flame detector using differential PIR sensors. Fire Safety Journal. 2012 Oct; 53:13–8. Crossref.
  • Kim CW, Ansari R, Cetin AE. A class of linear-phase regular biorthogonal wavelets. Proceedings of the IEEE ICASSP’92; 1992. p. 673–6. Crossref.
  • Toreyin BU, Soyer EB, Urfalioglu O, Cetin AE. Flame detection system based on wavelet analysis of PIR sensor signals with an HMM decision mechanism. Proceedings of EUSIPCO; 2008.
  • Phillips W, Shah M, da Vitoria Lobo N. Flame recognition in video. Pattern Recognition Letters. 2002; 23(1-3):319– 27. Crossref.

Abstract Views: 207

PDF Views: 0




  • Design of Electronic Security System in Restricted Areas on MSP430 Processor

Abstract Views: 207  |  PDF Views: 0

Authors

K. Rasool Reddy
Department of ECE, Gudlavalleru Engineering College, Vijayawada – 521356, Andhra Pradesh, India
M. H. Sundeep Singh
Department of ECE, Gudlavalleru Engineering College, Vijayawada – 521356, Andhra Pradesh, India
K. G. V. Nageswara Rao
Department of ECE, Gudlavalleru Engineering College, Vijayawada – 521356, Andhra Pradesh, India
M. Kama Raju
Department of ECE, Gudlavalleru Engineering College, Vijayawada – 521356, Andhra Pradesh, India

Abstract


In present day’s security from unauthorized humans (intruders) and fire/flame is one of the essential concerns especially in industries, banks, airports, railway stations and other restricted areas. Therefore, we introduce an Electronic Security System (ESS). The ESS provides the attentive message from flame as well as intruders. The proposed system generally consists of 3 devices namely PIR sensors, MSP430 and GSM. The flames and intruder are recognized by PIR. These activities are feeding to HMM, which are synthesized by wavelet transform. When there is an action occurs within the sensor range, then signal from sensor is processed by biorthogonal wavelet transform and then feeding to HMMs. The detection of intruder and flame is updated according to the HMM producing the highest probability. After that the alert message is sent to authorize person using GSM.

References





DOI: https://doi.org/10.17485/ijst%2F2018%2Fv11i23%2F114416