Open Access Open Access  Restricted Access Subscription Access

Faults Detection in EPDS through a BEAGLEBONE Black Card


Affiliations
1 Laboratory of Electrical Engineering and Energy Systems, IBN Tofail University, Kenitra, Morocco
2 Laboratory of Signals, Systems and Components, Sidi Mohamed Ben Abdellah University, Fez, Morocco
 

Objectives: The fault detection in Electrical Power Distribution Systems through a Beaglebone Black card made on a low voltage. Methods: This paper aims to validate the good functioning of the system, especially the display and the safeguarding of the signal of fault. For these tests, we realized a card of conditioning able to register samples for three seconds of the signals of the departure, of which the values, before and after defect, necessary for the application of fault detection algorithms. Findings: This work opens the door to the evaluation of the algorithm on real networks. Applications: The goal of this work is to reduce the intervention time and the repetitive power outages according to the behavior of the signal at the moment of the fault.

Keywords

Beaglebone Black Card, Electric Power Distribution Systems, Fault Location, Faults Detection
User

Abstract Views: 194

PDF Views: 0




  • Faults Detection in EPDS through a BEAGLEBONE Black Card

Abstract Views: 194  |  PDF Views: 0

Authors

Hamid Touijer
Laboratory of Electrical Engineering and Energy Systems, IBN Tofail University, Kenitra, Morocco
Youssef Menchafou
Laboratory of Signals, Systems and Components, Sidi Mohamed Ben Abdellah University, Fez, Morocco
Hassan El Markhi
Laboratory of Signals, Systems and Components, Sidi Mohamed Ben Abdellah University, Fez, Morocco
Mustapha Zahri
Laboratory of Electrical Engineering and Energy Systems, IBN Tofail University, Kenitra, Morocco
Mohamed Habibi
Laboratory of Electrical Engineering and Energy Systems, IBN Tofail University, Kenitra, Morocco

Abstract


Objectives: The fault detection in Electrical Power Distribution Systems through a Beaglebone Black card made on a low voltage. Methods: This paper aims to validate the good functioning of the system, especially the display and the safeguarding of the signal of fault. For these tests, we realized a card of conditioning able to register samples for three seconds of the signals of the departure, of which the values, before and after defect, necessary for the application of fault detection algorithms. Findings: This work opens the door to the evaluation of the algorithm on real networks. Applications: The goal of this work is to reduce the intervention time and the repetitive power outages according to the behavior of the signal at the moment of the fault.

Keywords


Beaglebone Black Card, Electric Power Distribution Systems, Fault Location, Faults Detection



DOI: https://doi.org/10.17485/ijst%2F2018%2Fv11i7%2F170438