Open Access Open Access  Restricted Access Subscription Access

Analysis of Cold-Formed C-Beam and Built Up Beam


Affiliations
1 Department of Civil Engineering, Vel Tech High Tech Dr. Rangarajan Dr. Sakunthala Engineering College, Chennai - 600062, Tamil Nadu, India
 

Objective: This project deals with the experimental investigation of the two cold formed C beams, two cold-formed built-up C beams and one hot-rolled I beam. Methods/Statistical Analysis: An experimental setup is placed the specimens on the loading frame for static loading and cyclic loading for the C beams and I beam section. The load is applied axially along the centroid of the beam and it is distributed into two points loading by distributor. Findings: Determined the load and deflection behavior, stiffness, energy absorption and ductility with the number of cycles evaluated for cold-formed C beam and hot-rolled I beam. Applications: The load carrying capacity increases for the built-up member when compared to the ordinary member. Cold-formed beams are preferred to hot-rolled beams when thermal insulation, light weight nature, easy moulding and economy is considered.


Keywords

Built-Up, C Beams, Cyclic Loading and One Hot-Rolled I Beam
User

Abstract Views: 137

PDF Views: 0




  • Analysis of Cold-Formed C-Beam and Built Up Beam

Abstract Views: 137  |  PDF Views: 0

Authors

G. Jenitha
Department of Civil Engineering, Vel Tech High Tech Dr. Rangarajan Dr. Sakunthala Engineering College, Chennai - 600062, Tamil Nadu, India
V. Gokul Nath
Department of Civil Engineering, Vel Tech High Tech Dr. Rangarajan Dr. Sakunthala Engineering College, Chennai - 600062, Tamil Nadu, India
N. Ganesh Kumar
Department of Civil Engineering, Vel Tech High Tech Dr. Rangarajan Dr. Sakunthala Engineering College, Chennai - 600062, Tamil Nadu, India

Abstract


Objective: This project deals with the experimental investigation of the two cold formed C beams, two cold-formed built-up C beams and one hot-rolled I beam. Methods/Statistical Analysis: An experimental setup is placed the specimens on the loading frame for static loading and cyclic loading for the C beams and I beam section. The load is applied axially along the centroid of the beam and it is distributed into two points loading by distributor. Findings: Determined the load and deflection behavior, stiffness, energy absorption and ductility with the number of cycles evaluated for cold-formed C beam and hot-rolled I beam. Applications: The load carrying capacity increases for the built-up member when compared to the ordinary member. Cold-formed beams are preferred to hot-rolled beams when thermal insulation, light weight nature, easy moulding and economy is considered.


Keywords


Built-Up, C Beams, Cyclic Loading and One Hot-Rolled I Beam



DOI: https://doi.org/10.17485/ijst%2F2016%2Fv9i2%2F130197