Open Access Open Access  Restricted Access Subscription Access

Simultaneous Spectrophotometric Estimation of Valsartan and Amlodipine Besylate by Dual Wavelength Method in Tablet Dosage form


Affiliations
1 Shri Ram Institute of Technology, Pharmacy, Near ITI Madhotal, Jabalpur- 482002, (M.P.), India
2 B.M.College of Pharmaceutical Education and Research, Vlll. Gokanya, Umarikeda, Khandwa Road, Indore- 452001, (M.P.), India
 

A simple and rapid spectrophotometric dual wavelength method has been developed for simultaneous estimation of amlodipine besylate and valsartan in tablet dosage form. Two wavelengths selected were 227 and 244nm, for estimation of valsartan and 360 nm for amlodipine besylate using methanol as a solvent. Both the drugs obeyed Beer-Lambert's law over the concentration range 5-100μg/ml and 5-50μg/ ml for valsartan and amlodipine besylate. The r2 for valsartan and amlodipine besylate were 0.9982 and 0.9973 with mean percent recovery of 100.23 and 99.66 respectively. The Relative standard deviations for validation parameters were found to be less then the 5%.

Keywords

Amlodipine Besylate, Valsartan, Tablet, Spectrophotometric Method.
User
Notifications
Font Size


Abstract Views: 154

PDF Views: 76




  • Simultaneous Spectrophotometric Estimation of Valsartan and Amlodipine Besylate by Dual Wavelength Method in Tablet Dosage form

Abstract Views: 154  |  PDF Views: 76

Authors

Ashish Jain
Shri Ram Institute of Technology, Pharmacy, Near ITI Madhotal, Jabalpur- 482002, (M.P.), India
Apoorvi Sharma
Shri Ram Institute of Technology, Pharmacy, Near ITI Madhotal, Jabalpur- 482002, (M.P.), India
Mukesh Bhaisare
B.M.College of Pharmaceutical Education and Research, Vlll. Gokanya, Umarikeda, Khandwa Road, Indore- 452001, (M.P.), India
S. Banerjee Pooja
Shri Ram Institute of Technology, Pharmacy, Near ITI Madhotal, Jabalpur- 482002, (M.P.), India
Megha Sharma
Shri Ram Institute of Technology, Pharmacy, Near ITI Madhotal, Jabalpur- 482002, (M.P.), India

Abstract


A simple and rapid spectrophotometric dual wavelength method has been developed for simultaneous estimation of amlodipine besylate and valsartan in tablet dosage form. Two wavelengths selected were 227 and 244nm, for estimation of valsartan and 360 nm for amlodipine besylate using methanol as a solvent. Both the drugs obeyed Beer-Lambert's law over the concentration range 5-100μg/ml and 5-50μg/ ml for valsartan and amlodipine besylate. The r2 for valsartan and amlodipine besylate were 0.9982 and 0.9973 with mean percent recovery of 100.23 and 99.66 respectively. The Relative standard deviations for validation parameters were found to be less then the 5%.

Keywords


Amlodipine Besylate, Valsartan, Tablet, Spectrophotometric Method.