Evaluation of Impact of Chemical Treatment on Clogged Drip Irrigation System


Affiliations
1 Department of Agricultural Engineering, College of Agriculture, Dhule (M.S.), India
2 College of Agriculture, Muktainagar, Jalgaon (M.S.), India
     

   Subscribe/Renew Journal


The experiment was conducted on farmer’s field at Vivare, Tal-Raver, dist-Jalgaon to study the impact of chemical treatments on clogged drip irrigation system.Total 27 laterals of 12mm diameter having length 25 meters each, on which 20 clogged emitters of 4 l ph discharge were mounted at a spacing of 1.25 m. The discharge of 10 emitters from each lateral was measured at a pressure of 1 kg/cm2 for 5 minutes before treatment. The three types of acid that is hydrochloric acid (35 % conc.), sulphuric acid (98% conc.) and nitric acid (60% conc.) were used for acid treatment. The acid treatment was given at different pH levels viz., 3, 3.5 and 4 pH.It was found that when the pH of water was greater than 7.0, precipitation of salts occurred in the drippers. The water having electrical conductivity 1.45 mmhos/cm when passed through the drip system, most of emitters were clogged. The uniformity co-efficient of drip system before and after acid treatment was 84.03 per cent and 96.20 per cent, respectively. The average percentage reductions in discharge of clogged emitters were observed in between 42.5 per cent to 45 per cent. The average percentage increased in discharge was observed 68.18 per cent when clogged emitter was treated with HC1 (35% cone.) having 3 pH cone. The best chemical treatment of hydrochloric acid (35% cone.) having 3 pH was more effective to water having electrical conductivity 1.45mmhos/cm for obtaining maximum discharge.

Keywords

Drip Irrigation, Clogging, Chemical Treatment, Uniformity Co-Efficient.
Subscription Login to verify subscription
User
Notifications
Font Size


  • Bresler, E.G. (1977). Trickle-drip irrigation principle and application to soil water management. Adv. Agron., 29 : 343-394.
  • Bucks, D.A., Nakayama, F.S. and Gilbert, R.G. (1980). Trickle irrigation, water quality and preventive maintenance. Agric. Water Mgmt., 2 :149-162.
  • Christiansen, J. E. (1942). Irrigation by sprinkling. California Agriculture Experiment Station Bulletin, No. 670, University of California, Berkley, U.S.A.
  • Gaikwad, D.T. (2000). Field evaluation of hydraulic of drip irrigation laterals on slopping land. M.Tech. Thesis, Mahatma Phule Krishi Vidyapeeth, Rahuri, Ahmednagar, M.S. (India), 144
  • Gorantiwar, S.D., Atre, A.A. and Shikhare, A.W. (1998). Emission uniformity of drip tubing. Souvenir of XXXIII.Ann. Con .ISAE September.21-23,(1998) at CIAE Bhopal, India. 119.
  • Meyer, L. L. (1985).Cleaning of drip irrigation system. In drip irrigation action J. ASAE.,1 : 40-44.
  • Micheal, A.M. (1978). Irrigation theory and practicles, Vikas Publication House Pvt.Ltd. New Delhi, India 1-801.
  • Thate, T.B. (2001). Study on extent of emitter clogging in drip irrigation system influenced by qulity of irrigation of water and fertigation. M.Sc. (Ag.) Thesis, Mahatma Phule Krishi Vidyapeeth, Rahuri, Ahmednagar, M.S. (India), 1-63.
  • Wu, I.P. and Gitlin, H.M. (1974). Drip irrigation design based on uniformity. Trans. ASAE ,17 (3) : 429-432.

Abstract Views: 193

PDF Views: 0




  • Evaluation of Impact of Chemical Treatment on Clogged Drip Irrigation System

Abstract Views: 193  |  PDF Views: 0

Authors

S. P. Nikam
Department of Agricultural Engineering, College of Agriculture, Dhule (M.S.), India
P. G. Pophale
College of Agriculture, Muktainagar, Jalgaon (M.S.), India

Abstract


The experiment was conducted on farmer’s field at Vivare, Tal-Raver, dist-Jalgaon to study the impact of chemical treatments on clogged drip irrigation system.Total 27 laterals of 12mm diameter having length 25 meters each, on which 20 clogged emitters of 4 l ph discharge were mounted at a spacing of 1.25 m. The discharge of 10 emitters from each lateral was measured at a pressure of 1 kg/cm2 for 5 minutes before treatment. The three types of acid that is hydrochloric acid (35 % conc.), sulphuric acid (98% conc.) and nitric acid (60% conc.) were used for acid treatment. The acid treatment was given at different pH levels viz., 3, 3.5 and 4 pH.It was found that when the pH of water was greater than 7.0, precipitation of salts occurred in the drippers. The water having electrical conductivity 1.45 mmhos/cm when passed through the drip system, most of emitters were clogged. The uniformity co-efficient of drip system before and after acid treatment was 84.03 per cent and 96.20 per cent, respectively. The average percentage reductions in discharge of clogged emitters were observed in between 42.5 per cent to 45 per cent. The average percentage increased in discharge was observed 68.18 per cent when clogged emitter was treated with HC1 (35% cone.) having 3 pH cone. The best chemical treatment of hydrochloric acid (35% cone.) having 3 pH was more effective to water having electrical conductivity 1.45mmhos/cm for obtaining maximum discharge.