Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Development and Validation of High Performance Liquid Chromatographic Method for Estimation of Deflazacort in Pharmaceutical Formulation


Affiliations
1 Appasaheb Birnale College of Pharmacy, South-Shivaji Nagar, Sangli 416416 (MS), India
     

   Subscribe/Renew Journal


A simple, selective, rapid and precise reverse phase HPLC method has been developed for the estimation of Deflazacort in pharmaceutical dosage form. A Hypersil BDS C18 (250 mm X 4.6mm) column was used for separation. The mobile phase was ammonium acetate buffer solution: acetonitrile (50:50 v/v). Flow rate 1.0ml/min with detection at 254 nm. The retention time of Deflazacort was 6.03min. Linearity obtained in the concentration range of 20-100μg/ml with correlation coefficient of 0.998.The result of the analysis were validated statistically and recovery studies confirmed by the accuracy of the proposed method. The proposed RP-HPLC method for the estimation of Deflazacort in dosage form is accurate, precise, linear, robust, simple, rapid and selective.


Keywords

RP-HPLC, Deflazacort.
Subscription Login to verify subscription
User
Notifications
Font Size


Abstract Views: 194

PDF Views: 1




  • Development and Validation of High Performance Liquid Chromatographic Method for Estimation of Deflazacort in Pharmaceutical Formulation

Abstract Views: 194  |  PDF Views: 1

Authors

D. D. Chougule
Appasaheb Birnale College of Pharmacy, South-Shivaji Nagar, Sangli 416416 (MS), India
N. S. Naikwade
Appasaheb Birnale College of Pharmacy, South-Shivaji Nagar, Sangli 416416 (MS), India

Abstract


A simple, selective, rapid and precise reverse phase HPLC method has been developed for the estimation of Deflazacort in pharmaceutical dosage form. A Hypersil BDS C18 (250 mm X 4.6mm) column was used for separation. The mobile phase was ammonium acetate buffer solution: acetonitrile (50:50 v/v). Flow rate 1.0ml/min with detection at 254 nm. The retention time of Deflazacort was 6.03min. Linearity obtained in the concentration range of 20-100μg/ml with correlation coefficient of 0.998.The result of the analysis were validated statistically and recovery studies confirmed by the accuracy of the proposed method. The proposed RP-HPLC method for the estimation of Deflazacort in dosage form is accurate, precise, linear, robust, simple, rapid and selective.


Keywords


RP-HPLC, Deflazacort.