Condition Assessment Techniques for Insulation Diagnosis of Oil Filled Power Transformers


Affiliations
1 Central Power Research Institute (CPRI), Bengaluru – 560080, Karnataka, India
     

   Subscribe/Renew Journal


Power transformers are key components in the substation/switchyard and failure of transformer can have an enormous impact on reliability and availability of power supply and has financial implications. As there is ever increase in demand of power, the reliability of power equipment assumes high importance. Economic factors are the main consideration and in order to minimize capital expenditure on new equipment, it is a common policy among utilities to maximize the use of existing power transformers by operating at their design capability. This can be achieved by periodic diagnostic testing and adopting condition based maintenance practices. In this paper various condition assessment techniques for oil filled transformers are discussed and few case studies are presented.

Keywords

Condition Assessment, Generator Transformer, Insulation Diagnosis, SFRA
User
Subscription Login to verify subscription
Notifications
Font Size

  • Chakravorti S, Dey D, Chatterjee B. Recent trends in the condition monitoring of transformers-theory, implementation and analysis.
  • IEEE Std. 62-1995 IEEE guide for diagnostic field testing of electric power apparatus-Part1 oil filled transformers, regulators and reactors. IEEE Xplore Digital Library; 1995 Dec 1.
  • IEC Std. 60076-18, power transformer Part-18: Measurement of frequency response. International Electrotechnical Commission (IEC); 2012 Jul.
  • Lifetime Evaluation of transformers. CIGRE Working Group 12.09; 1993.
  • Pradhan MK, Ramu TS. On estimation of elapsed life of oil-immeresed power transformers. IEEE Transactions on Power Delivery. 2005; 20(3):1962–9.

Abstract Views: 221

PDF Views: 0




  • Condition Assessment Techniques for Insulation Diagnosis of Oil Filled Power Transformers

Abstract Views: 221  |  PDF Views: 0

Authors

Dillip Kumar Puhan
Central Power Research Institute (CPRI), Bengaluru – 560080, Karnataka, India
Rajat Sharma
Central Power Research Institute (CPRI), Bengaluru – 560080, Karnataka, India
K. P. Meena
Central Power Research Institute (CPRI), Bengaluru – 560080, Karnataka, India
B. Nageshwar Rao
Central Power Research Institute (CPRI), Bengaluru – 560080, Karnataka, India

Abstract


Power transformers are key components in the substation/switchyard and failure of transformer can have an enormous impact on reliability and availability of power supply and has financial implications. As there is ever increase in demand of power, the reliability of power equipment assumes high importance. Economic factors are the main consideration and in order to minimize capital expenditure on new equipment, it is a common policy among utilities to maximize the use of existing power transformers by operating at their design capability. This can be achieved by periodic diagnostic testing and adopting condition based maintenance practices. In this paper various condition assessment techniques for oil filled transformers are discussed and few case studies are presented.

Keywords


Condition Assessment, Generator Transformer, Insulation Diagnosis, SFRA

References





DOI: https://doi.org/10.33686/prj.v14i2.144706