Refine your search
Collections
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z All
Gangwar, Sakshi
- A Customized Impression Technique for Highly Placed Mal-Aligned Implant for a Hybrid Over Denture Patient:A Case Report
Abstract Views :222 |
PDF Views:1
Authors
Affiliations
1 Professor and Head, Depatment of Prosthodontics (Implantology Division), Institute of Dental Sciences, Bareilly - 243006, Uttar Pradesh, IN
2 Professor and Head, Department of Oral and Maxillofacial Surgery, Institute of Dental Sciences, Bareilly - 243006, Uttar Pradesh, IN
3 MDS, 3rd year Student, Institute of Dental Sciences, Bareilly - 243006, Uttar Pradesh, IN
1 Professor and Head, Depatment of Prosthodontics (Implantology Division), Institute of Dental Sciences, Bareilly - 243006, Uttar Pradesh, IN
2 Professor and Head, Department of Oral and Maxillofacial Surgery, Institute of Dental Sciences, Bareilly - 243006, Uttar Pradesh, IN
3 MDS, 3rd year Student, Institute of Dental Sciences, Bareilly - 243006, Uttar Pradesh, IN
Source
Journal of Pierre Fauchard Academy (India Section), Vol 34, No 1 (2020), Pagination: 36-39Abstract
A hybrid implant denture is a fixed prosthesis over a metal framework and engaged by screws into the implant abutments. The anterior and posterior part of a mandibular hybrid denture is rigid on implants. Implant supported hybrid prosthesis provide satisfactory results on the mastication, esthetics and phonetics. This article describes a customized impression technique for highly mal aligned placed implants for hybrid implant denture. The total of five implants was present in the mandibular arch. Author advocates surveying of mal aligned implant analogue cast. The current technique depicts a customized resin impression tray with open border at two sites that concomitant at highly mal aligned implant position (canine region). Technique also uses the hard elastic chain for splinting of impression analogue. Final impression is recorded with single putty wash technique with polyvinyl siloxane elastomeric material. Although, technique is quite clinical sensitive. Asserting over this technique, it eliminates the use of transmucosal or multi unit abutments. This advocated technique is also economical for both clinician and patient. Impression was quite satisfactory.Keywords
Customized Impression Tray, Elastic Chain, Mal-Placed Implants, Ney’s Surveyor.References
- Chai JY, Jameson LM, Moser JB, Hesby RA. Adhesive properties of several impression material systems: part 2. J Prosthet Dent. 1991; 66: 287–292. https://doi.org/10.1016/0022-3913(91)90251-Q
- Pande NA, Parkhedkar RD. An evaluation of dimensional accuracy of one-step and two-step impression technique using addition silicone impression material: an in vitro study. J Indian Prosthodont Soc. 2013; 13: 254–9. https://doi.org/10.1007/s13191-012-0182-1
- Wadhwani CP, Johnson GH, Lepe X, Raigrodski AJ. Accuracy of newly formulated fastsetting elastomeric impression materials. J Prosthet Dent. 2005; 93: 530–9. https://doi.org/10.1016/j.prosdent.2005.03.007
- Kumari N, Nandeeshwar DB. The dimensional accuracy of polyvinyl siloxane impression materials using two different impression techniques: An in vitro study. J Indian Prosthodont Soc. 2015; 15: 211–15. https://doi.org/10.4103/0972-4052.158074
- Wadhwani CP, Johnson GH, Lepe X, Raigrodski AJ. Accuracy of newly formulated fastsetting elastomeric impression materials. J Prosthet Dent. 2005; 93: 530–9. https://doi.org/10.1016/j.prosdent.2005.03.007
- Kumari N, Nandeeshwar DB. The dimensional accuracy of polyvinyl siloxane impression materials using two different impression techniques: An in vitro study. J Indian Prosthodont Soc. 2015; 15: 211–15. https://doi.org/10.4103/0972-4052.158074
- Mahesh Lahori, Mahesh Lanka, Rahul Nagrath, Shweta Singh. An evaluation of the accuracy of multiple implant impression technique: An in vitro study. The Journal of implants and Advanced Clinical Dentistry 2012; 4: 57–69.
- Assif D, Marshak B, Schmidt A. Accuracy of implant impression techniques. Int J Oral Maxillofac Implants 1996; 11: 216–22. https://doi.org/10.1097/00008505-19960054000028
- N.A.Tarib, T W Seong, KM Chuen, MS Khan. Evaluation of Splinting implant impression Techniques: Two Dimensional Analyses: Eur J Prosthodont Rest Dent 2012; 20: 35–39.
- Misch CE. St. Louis, MO: Mosby Elsevier; 2008. Contemporary Implant Dentistry; p. 99. p. 100.
- Thalji G, Bryington M, De Kok IJ, Cooper LF. Prosthodontic management of implant therapy. Dent Clin North Am. 2014; 58: 207–25. https://doi.org/10.1016/j.cden.2013.09.007
- Yao, C., Lu, J., & Webster, T. J. Titanium and cobalt– chromium alloys for hips and knees. Biomaterials for Artificial Organs, 2011; pp. 34-55. https://doi.org/10.1533/9780857090843.1.34
- Prosthetic Management Following Anterior Segmental Mandibular Resection: A Case Report
Abstract Views :71 |
PDF Views:0
Authors
Affiliations
1 MDS, Senior Lecturer, Department of Prosthodontics, Institute of Dental Sciences, Bareilly - 243006, Uttar Pradesh, IN
2 MDS, Senior Lecturer, Department of Prosthodontics, Government Dental College, Dibrugarh - 786001, Assam, IN
3 MDS, Professor, Department of Prosthodontics, Institute of Dental Sciences, Bareilly - 243006, Uttar Pradesh, IN
1 MDS, Senior Lecturer, Department of Prosthodontics, Institute of Dental Sciences, Bareilly - 243006, Uttar Pradesh, IN
2 MDS, Senior Lecturer, Department of Prosthodontics, Government Dental College, Dibrugarh - 786001, Assam, IN
3 MDS, Professor, Department of Prosthodontics, Institute of Dental Sciences, Bareilly - 243006, Uttar Pradesh, IN
Source
Journal of Pierre Fauchard Academy (India Section), Vol 36, No 4 (2022), Pagination: 147-151Abstract
The rehabilitation of a patient in the Kennedy class IV situation demands biomechanical balance and aesthetic improvement. Larger defects usually lead to increased movement of the prosthesis, due to the compromised mucosal support and a longer edentulous span of the prosthesis. The article describes the prosthetic management of a patient following partial mandibular resection. The long span of missing teeth and the unavailability of a sufficient number of abutments are challenges for prostheses. This case report describes an inexpensive technique for the fabrication of attachment retained prosthesis over castable bar assembly for rehabilitating the long‑span Kennedy class IV situation.Keywords
Extracoronal Attachment, Hybrid Prosthesis, Kennedy Class IV Partial Denture, Segmental Mandibulectomy.References
- Carr AB, Brown DT. McCracken’s removable partial prosthodontics- E-Book. Elsevier Health Sciences; 2010 Jun 22.
- Beumer III J, Marunick MT, Esposito SJ. Maxillofacial rehabilitation: Prosthodontic and surgical management of cancer-related, acquired, and congenital defects of the head and neck. Quintessence Pub. 2011; 276.
- Joshi PR, Saini GS, Shetty P, Bhat SG. Prosthetic rehabilitation following segmental mandibulectomy. J. Indian Prosthodont Soc. 2008; 8:108-11. Available from: https://www.j-ips.org/text.asp?2008/8/2/108/43614 https://doi.org/10.4103/0972-4052.43614 DOI: https://doi.org/10.4103/0972-4052.43614
- Cheatham JL, Newland JR, Radentz WH, O’Brien R. The ‘fixed’ removable partial denture: Report of case. J Am Dent Assoc. 1984 Jul 1; 109(1):57-9. https://doi.org/10.14219/ jada.archive.1984.0256 PMid:6379018 DOI: https://doi.org/10.14219/jada.archive.1984.0256
- Jain AR. A prosthetic alternative treatment for severe anterior ridge defect using fixed removable partial denture Andrew’s bar system. World J Dent. 2013 Oct; DOI: https://doi.org/10.5005/jp-journals-10015-1246
- (4):282-5. Available from: https://www.researchgate. net/publication/269659514 https://doi.org/10.5005/ jp-journals-10015-1246
- Mundhe K, Pruthi G, Jain V. Prosthodontic rehabilitation of patient with marginal mandibular resection using attachment supported prostheses: A clinical report. Contemp Clin Dent. 2014Jan; 5(1):123. Available from: https://www.contempclindent.org/text.asp?2014 /5/1/123/128690 https://doi.org/10.4103/0976-237X. 128690 PMid:24808712 PMCid:PMC4012104 DOI: https://doi.org/10.4103/0976-237X.128690
- Singh K, Gupta N, Kapoor V, Gupta R. Hader bar and clip attachment retained mandibular complete denture. Case Reports. 2013 Oct 21; 2013:bcr2013010401. Available from: https://www.researchgate.net/publication/258064650 https://doi.org/10.1136/bcr-2013-010401 PMid:24145505 PMCid:PMC3822056 DOI: https://doi.org/10.1136/bcr-2013-010401
- Bhapkar P, Boyre A, Menon P, Gubrellay P. Andrew’s bridge system: An esthetic option. J Dent Sci. 2015; 4:36-40. Available from: https://www.jdas.in/text. asp?2015/4/1/36/167541 https://doi.org/10.4103/2277- 4696.167541 DOI: https://doi.org/10.4103/2277-4696.167541
- Everhart RJ, Cavazos Jr E. Evaluation of a fixed removable partial denture: Andrews bridge system. J Prosthet Dent. 1983 Aug 1; 50(2):180-4. https://doi.org/10.1016/0022- 3913(83)90008-2 PMid:6352902 DOI: https://doi.org/10.1016/0022-3913(83)90008-2
- VK, Nayakar RP, Patil R. Prosthetic rehabilitation of mandibular defects with fixed-removable partial denture prosthesis using precision attachment: A twin case report. Contemp Clin Dent 2017 Jul; 8(3):473. Available from: https://www.contempclindent.org/text. asp?2017/8/3/473/214525 https://doi.org/10.4103/ccd. ccd_117_17 PMid:29042738 PMCid:PMC5644010 DOI: https://doi.org/10.4103/ccd.ccd_117_17