Refine your search
Co-Authors
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z All
Venkateswarlu, G.
- Comparision of Anti-Larvacidal Activity of Cassia occidentalis, Bamboosa vulgaris and Sapindus mukurossi
Abstract Views :317 |
PDF Views:1
Authors
G. Venkateswarlu
1,
S. Manoranjan
1,
N. Sharada
1,
M. Sravan Prasad
2,
M. D. Azeez
1,
E. Rajeshwari
1
Affiliations
1 Venkateshwara Institute of Pharmaceutical Sciences, Cherlapally, Nalgonda-508001, IN
2 Sri Indu Institute of Pharmacy, Sheriguda, R.R Dist, IN
1 Venkateshwara Institute of Pharmaceutical Sciences, Cherlapally, Nalgonda-508001, IN
2 Sri Indu Institute of Pharmacy, Sheriguda, R.R Dist, IN
Source
Asian Journal of Pharmaceutical Research, Vol 2, No 3 (2012), Pagination: 118-119Abstract
The present study evaluates the Anti-larvacidal of methanolic extract of Cassia occidentalis leaf, Bamboosa Vulgaris and Mukundus Saprossi at various concentrations against malarial vector. The various plant extracts exhibited larvacidal activity at different time intervals (24 hrs and 48 hrs). The mosquito larva of LC 50 and LC 90 values of Cassia occidentalis for I instar larvae 60.69%, 119.74%, the II instar 64.76%, 121.60%, III instar 67.78%, 123.35%, IV instar 70.56%, 122.81% and pupa 92.21%, 162.52% respectively.Keywords
Cassia occidentalis, Bambusa valgaris, Sapindus mukurossi, Anti-Larvacidal, Dechlorinated Water.- Issues and Challenges for Women’s Participation in MGNREGS With Reference to Andhra Pradesh
Abstract Views :550 |
PDF Views:0
Authors
Affiliations
1 Dept. of Management Studies, Siddharth Institute of Engineering and Technology, Puttur, Andhra Pardesh, IN
1 Dept. of Management Studies, Siddharth Institute of Engineering and Technology, Puttur, Andhra Pardesh, IN
Source
Social Work Chronicle, Vol 6, No 1 (2017), Pagination: 90-95Abstract
Mahatma Gandhi National Rural Employment Guarantee Scheme (MNGREGS) is playing a vital role for rural people and helps to boost up the involvement of women in society and economy. There is inequality and vulnerability of women in all spheres of life. They need to be empowered in all walks of life. Without the active participation of women, establishment of a new social order may not be successful, because women constitute half of the population. It firmly states that the status of women would not change merely by bringing legislations;it must be supported by change in the women's social circumstances and situations and also in men's existing attitude towards women. The present paper studies the women's participation through MGNREGS in Andhra Pradesh and also the issues and challenges related to women participation in MGNREGS.Keywords
MGNREGS, Women Empowerment, Issues and Challenges.References
- Gnyaneswar, D. (2006). Women empowerment through MGNREGS. AIJRRLSJM, 1(7). ISSN: 2455-6602.
- Golden Research Thoughts. (2012). 2(3). ISSN: 2231-5063.
- Xavier, G., & Mari, G. (2014). Impact of MGNREGA on empowerment. SSRG-IJEMS, 1(1). ISSN: 2393-9125.
- www.nrega.ap.gov.in
- www.nrega.nic.in
- Interpretation of NSDD and Restrike in Capacitive Current Switching Test on Medium Voltage Vacuum Circuit Breaker
Abstract Views :224 |
PDF Views:0
Authors
Affiliations
1 Switchgear Testing and Development Station, Central Power Research Institute Govindpura, Bhopal – 462023, Madhya Pradesh, IN
1 Switchgear Testing and Development Station, Central Power Research Institute Govindpura, Bhopal – 462023, Madhya Pradesh, IN
Source
Power Research, Vol 17, No 2 (2021), Pagination: 81-87Abstract
Capacitor banks are installed in an increasing number to control power quality issues and improving the power factor to counteract the reactive power in the transmission and distribution networks. Due to load fluctuations switching of capacitor banks is a typical phenomenon. Capacitor bank is normally having concentrated capacitance in contrast with distributed capacitance. It generally draws more current than unloaded cableor line in practical cases up to several hundred amperes. Hence, switching of capacitor bank causes a very high rate of rise of transient recovery voltage across circuit breaker contacts. This scenario can be simulated in testing laboratories by a voltage source connected to a circuit breaker which again is connected to a large capacitance in terms of IEC called capacitive current switching test. Non-sustained disruptive discharge (NSDD) is a voltage breakdown after the vacuum circuit-breaker open the fault current which will not cause the recovery of power frequency current. Restrike is different from NSDD, the recovery of power frequency current between the contacts will make the breaker failed. It’s not easy to show the distinction between NSDD and restrike during some type tests. The paper presents the study of performance evaluation of the circuit breaker during the capacitor current switching duties. A statistical analysis of failure of circuit breaker during capacitor current switching tests are included in the paper to help the manufacturers & utilities, so that the care can be taken for trouble free services. The paper also discusses the changes made in the IEC 62271 – 100, Amendment1:2012 for conducting the capacitive current switching tests.Keywords
Capacitor Switching Duty Cycle, Non-sustained Disruptive Discharge (NSDD), Voltage Breakdown, Capacitive Current Switching Test,Current Switching Test, Inadequate Synchronization.References
- Thielens DW. Circuit Influences on Non-Sustained Disruptive Discharges in Vacuum Switching Devices. Eindhoven University, M.Sc. report S433649; 2003.
- Smeets RPP, Wiggers R, Bannink H, Kuivenhoven S, Chakraborty S, Sandolache G. The impact of switching capacitor banks with very high inrush current on switchgear. CIGRE Conference, paper A3; 2012.
- IEC 62271-100; 2008.
- IEEE C37.012.
- Smeets RPP, Lathouwers AGA, Falkingham LT. Assessment of Non-Sustained Disruptive Discharges (NSDD) in Switchgear. Test experience and standardisation status. CIGRE Conference, paper A3-303; 2004.