Refine your search
Collections
Co-Authors
Journals
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z All
Mohan, D.
- Book Reviews
Abstract Views :242 |
PDF Views:0
Authors
Source
Indian Forester, Vol 138, No 10 (2012), Pagination: 975-975Abstract
No Abstarct- Metal Ion Removal from the Aqueous Feed Using PVDF/PS Blend Ultrafiltration Membranes
Abstract Views :427 |
PDF Views:113
Authors
K. H. Shobana
1,
D. Mohan
2
Affiliations
1 Deparment of Physics, Saveetha Engineering College, Thandalam, Chennai- 602 105, IN
2 Membrane Laboratory, Department of Chemical Engineering, A.C.College of Technology, Anna University, Chennai- 600 025, IN
1 Deparment of Physics, Saveetha Engineering College, Thandalam, Chennai- 602 105, IN
2 Membrane Laboratory, Department of Chemical Engineering, A.C.College of Technology, Anna University, Chennai- 600 025, IN
Source
Indian Journal of Science and Technology, Vol 3, No 6 (2010), Pagination: 663-666Abstract
Polyvinyledenefluoride-polystyrene (PVDF/PS) blend ultrafiltration membranes were prepared using phase inversion technique. Casting solutions were prepared with different compositions of poly (vinylidene fluoride) (PVDF) and polystyrene (PS) both in the presence and absence of the additive, poly (vinylpyrolidone) (PVP) using dimethylacetamide as solvent. The effects of compositions of PS and concentrations of PVP on shrinkage ratio, pure water flux and percentage of water content of the blend ultrafiltration membranes were studied. The application of the PVDF/PS blend membranes in separation of toxic heavy metal ions from aqueous streams was also attempted and the results are discussed.Keywords
Ultrafiltration Membrane, Heavy Metal SeparationReferences
- Fox TG and Flory PJ (1954) The glass temperature and related properties of polystyrene. Influence of molecular weight. J. Polymer Sci. 15, 315–319.
- Jarvis NV and Wagener JM (1995) Mechanical study of metal ion binding to water soluble polymers using potentiometry. Talanta. 12(2), 219-226.
- Kobayashi S, HiroishiK, Tokunoh M and saegusa T (1987) Chelating properties of linear and branched poly (ethyleneimines). Macromolecules. 20, 1496–1500.
- Yeow ML., Liu Y and Li K (2005).Preparation of porous PVDF hollow fibre membrane via a phase inversion method using lithium perchlorate (LiClO4) as an additive. J. Membrane Sci. 258, 16 -22.
- Malaisamy R and Mohan D (2002) Polyurethane and sulfonated polysulfone blend ultrafiltration membranes. Part 1: Preparation and characterization. J. Col. Inter. Sci. 254, 129-140.
- Malaisamy R, Mahendran R, Mohan D, Rajendran M and Mohan V (2002) Cellulose acetate and Sulfonated Polysulfone blend ultrafiltration membranes I. Preparation and characterization. J. Membrane Sci. 86, 1749-1761.
- Pereiranunes S and Peinemann KV (1992) Ultrafiltration membranes from PVDF/PMMA blends. J. Membrane Sci. 73, 25-35.
- Sajitha CJ, Mahendran R and Mohan D (2002) Studies on cellulose acetate and carboxylated polysulfone blend ultrafiltration membranes–Part 1. Euro. Polym. J. 38, 2507-2511.
- Wu L, Sun J and Wang Q (1996) Poly (vinylidenefluoride)/polyethersulfone blend membranes: Effects of solvent sort, polyethersulfoneand polyvinylpyrrolidone concentration on theirproperties and morphology. J. Membrane Sci. 113, 361–371.
- Xue S and Yin G (2006) Proton exchange membranes based on poly (vinylidene fluoride) and sulfonated poly (ether ether ketone). Polymer. 47, 5044-5049.
- Yang MC and Liu TY (2003) The permeation performance of polyacrylonitrile/polyvinylidine fluoride blend membranes. J. Membrane Sci. 226(1-2), 119-130.
- Young RJ and Lovell PA (1991) Introduction to polymers, 2nd ed., Champman & Hall, London. p:443.
- Multi Carrier PWM Strategies for Eleven Level Cascaded Multi Level Inverter
Abstract Views :208 |
PDF Views:1
Authors
Affiliations
1 Department of Electrical and Electronics Engineering, Annai Mathammal Sheela Engineering College, Namakkal, IN
2 KEC International LTD, UNNAO, Uttar Pradesh, IN
1 Department of Electrical and Electronics Engineering, Annai Mathammal Sheela Engineering College, Namakkal, IN
2 KEC International LTD, UNNAO, Uttar Pradesh, IN
Source
Programmable Device Circuits and Systems, Vol 4, No 2 (2012), Pagination: 91-94Abstract
In recent years multi level inverters are used high power and high voltage applications. In this paper propose PWM control strategy an eleven level cascaded H-bridge multi level inverter. This method introduce sine wave is compared with the triangular carrier wave with different phase relationship. The carrier based Phase disposition PDPWM, PODPWM, APODPWM have been analyzed in this paper. The PWM control strategy method for multi level inverter to reduce the total harmonics distortion in the output waveform. The simulation is done by matlab/simulink environment.Keywords
Pulse Width Modulation, SPWM, PDPWM, PODPWM, APODPWM.- Performance Analysis of Multi Level Shunt Active Filter Based on SDM
Abstract Views :160 |
PDF Views:3
Authors
Affiliations
1 Department of Electrical and Electronics Engineering, A.C. College of Engineering and Technology, Karaikudi, IN
2 KEC International LTD, UNNAO, Uttar Pradesh, IN
3 Department of Electrical and Electronics Engineering, AMS Engineering College, Namkkal, IN
4 Department of Applied Science, Paavai Engineering College, Pachal, Namakkal, IN
1 Department of Electrical and Electronics Engineering, A.C. College of Engineering and Technology, Karaikudi, IN
2 KEC International LTD, UNNAO, Uttar Pradesh, IN
3 Department of Electrical and Electronics Engineering, AMS Engineering College, Namkkal, IN
4 Department of Applied Science, Paavai Engineering College, Pachal, Namakkal, IN
Source
Digital Signal Processing, Vol 3, No 2 (2011), Pagination: 42-46Abstract
A new shunt active filter is proposed here to reduce the harmonic contents in source voltage and source currents of a harmonic polluted three phase system supplying a non – linear load. The shunt active filter is designed with multi level cascaded H-bridge inverter. To generate the required compensation currents multi carrier PWM Currents are extracted from the load power using Synchronous Detection Method. Simulation of the active filter with proposed current control and dc bus control is presented. The harmonic filter reduces the harmonic contents in source currents as well as the source voltage multilevel shunt active filter does not require an interfacing transformer to connect it with the high power system. It reduces the filter current ripples and improve source power factor.Keywords
Point of Common Coupling (PCC), Synchronous Detection Method (SDM), Multi-Carrier Pulse Width Modulation, Total harmonic Distortion (THD).- Experimental Investigation of Heat Transfer Study on Plate Fin Heat Exchangers with Wavy Fins
Abstract Views :227 |
PDF Views:0
Authors
Affiliations
1 Department of Mechanical Engineering, SRM University, Kattankulathur - 603203, Kancheepuram District, Tamil Nadu, IN
1 Department of Mechanical Engineering, SRM University, Kattankulathur - 603203, Kancheepuram District, Tamil Nadu, IN