Refine your search
Collections
Co-Authors
Journals
Year
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z All
Ghoroi, Chinmay
- Development of a Unique Full-Scale Real-Fire Facade Testing Facility at IIT Gandhinagar
Abstract Views :189 |
PDF Views:79
Authors
Gaurav Srivastava
1,
Chinmay Ghoroi
2,
Pravinray Gandhi
3,
V. Jagdish
4,
G. Karthikeyan
4,
Aravind Chakravarthy
4,
Dharmit Nakrani
1
Affiliations
1 Department of Civil Engineering, IIT Gandhinagar, Palaj, Gandhinagar 382 255, IN
2 Department of Chemical Engineering, IIT Gandhinagar, Palaj, Gandhinagar 382 255, IN
3 Underwriters Laboratories, LLC, 333 Pfingston Rd, Northbrook, IL 60062, US
4 Underwriters Laboratories India Pvt Ltd, Block 1, Klgani Platina, ERIP Zone, Whitefield Road, Bengaluru 560 066,, IN
1 Department of Civil Engineering, IIT Gandhinagar, Palaj, Gandhinagar 382 255, IN
2 Department of Chemical Engineering, IIT Gandhinagar, Palaj, Gandhinagar 382 255, IN
3 Underwriters Laboratories, LLC, 333 Pfingston Rd, Northbrook, IL 60062, US
4 Underwriters Laboratories India Pvt Ltd, Block 1, Klgani Platina, ERIP Zone, Whitefield Road, Bengaluru 560 066,, IN
Source
Current Science, Vol 115, No 9 (2018), Pagination: 1782-1787Abstract
Most modern buildings incorporate a façade system to conform to green building regulations. Several common facade systems utilize composite panels made of combustible materials and can significantly enhance the fire risk, as shown by many recent building fires. This study presents the development of a full-scale research facility at IIT Gandhinagar to better understand the behaviour of real fires involving façade systems. Such a facility will facilitate scientific studies pertaining to façade fires and help in improving fire safety of such buildings.Keywords
Facade Testing Facility, Green Building Regulations, Leap Frog Effect, Real-Fire Behaviour.References
- Peng, L., Ni, Z. and Huang, X., Review on the fire safety of exterior wall claddings in high-rise buildings in China. Proc. Eng., 2013, 62, 663–670.
- Kim, Y., Mizuno, M. and Ohmiya, Y., Fire examination of superhighrise apartment building ‘Wooshin Golden Suites’ in Busan, Korea. Fire Sci. Technol., 2011, 30(3), 81–90.
- Badrock, G., Post incident analysis report: Lacrosse Docklands. In MATEC Web of Conferences, 25 November 2014, 2016, vol. 46, pp. 06002.
- White, N. and Delichatsios, M., Fire hazards of exterior wall assemblies containing combustible components. The Fire Protection Research Foundation, MA, USA, 2014.
- IS 1642, Fire safety of buildings (general): details of construction – code of practice. Bureau of Indian Standards, New Delhi, 1989.
- IS 1239, Mild steel tubes, tubular and other wrought steel fittings – specification, Bureau of Indian Standards, New Delhi, 2011.