The current article discusses the study of the Development and Performance Investigation of a Solar Concrete Collector at Different Climatic Conditions. The solar concrete collector is a modification over conventional solar water heaters. This concrete is mainly made up of sand and cement. The solar concrete collector with an area of 2 m2 has been developed and tested for all three seasons, i.e., rainy, winter, and summer seasons. The inlet water temperatures and outlet water temperatures have been recorded along with corresponding solar intensities for any five successive days in a month. A family of 5–6 peoples requires about 130–150 liters of water daily for bathing and other purposes. So, we have selected a flow rate of 30 liters per hour of water. These observations have been recorded between 12:00 and 16:00PM. Also, hot water temperatures stored in an isolated storage tank are recorded the very next morning. An arrangement consists of K-type thermocouples, a 12-channel temperature indicator, and a pyranometer. Using recorded observations, the performance of a solar concrete collector has been determined.

Keywords

Solar Concrete Collector, Pyranometer, Solar Intensity, Thermocouple, Temperature Indicator.
User
Notifications
Font Size

  • Sukhatme S P, Nayak J K, Solar Energy, ( McGraw Hill Education, India), 4th Edn, ISBN: 9352607112, 2017, p. 202.
  • Keste A A, Patil S , J Mech & Civil engg , 2, (2013), 26.
  • Sabale A , Int J Renewable Ener research, 7(02),(2017), 51.
  • Krishnavel V , Karthick A , Kalidasa Murugavel K , Energy and Buildings, 84,(2014) 501.
  • Hazami M , Kooli S , Lazâar M , Farhat A, Belghith A, Energy Convers Manage, 51, (2010) 1210.
  • Waghmare P M , Sollapur SB, Wange S.M, Lect Notes in Ele Engg Springer, 435, (2018) 467.
  • Qianmin M, Rongxin G, Zhiman Z, Zhiwei L, Kecheng H, Constr Build Material, 93, (2015), 371.
  • Mundle H G, Int J Res Eng Technol, 2 (2), (2014) 149.
  • Mohod M V, Int J Eng Sci, 1 (12), (2012), 1.
  • Vikrant S Vairagade, Kavita S Kene, Int. J Sci Techno. Res, 1 (4), (2012) 139.
  • Rana A, Int J Emerg Tech- nol Adv Eng, 3 (1) (2013), 120.
  • Sarachittia R, Chotetanormb C, Lertsatitthanakornb c, Rungsiyopasc M., Energy and Buildings, 43, (2011) 1403.

Abstract Views: 74

PDF Views: 80




  • Development and Performance Investigation of Solar Concrete Collector at Different Climatic Conditions

Abstract Views: 74  |  PDF Views: 80

Authors

Pratik M Waghmare
Department of Mechanical Engineering, Savitribai Phule Pune University, Pune 411 007, India
Shrishail B Sollapur
Department of International Institute for Aerospace Engineering and Management (IIAEM), Faculty of Engineering and Technology, JAIN (Deemed to be University), Bengaluru 560 069, India

Abstract


The current article discusses the study of the Development and Performance Investigation of a Solar Concrete Collector at Different Climatic Conditions. The solar concrete collector is a modification over conventional solar water heaters. This concrete is mainly made up of sand and cement. The solar concrete collector with an area of 2 m2 has been developed and tested for all three seasons, i.e., rainy, winter, and summer seasons. The inlet water temperatures and outlet water temperatures have been recorded along with corresponding solar intensities for any five successive days in a month. A family of 5–6 peoples requires about 130–150 liters of water daily for bathing and other purposes. So, we have selected a flow rate of 30 liters per hour of water. These observations have been recorded between 12:00 and 16:00PM. Also, hot water temperatures stored in an isolated storage tank are recorded the very next morning. An arrangement consists of K-type thermocouples, a 12-channel temperature indicator, and a pyranometer. Using recorded observations, the performance of a solar concrete collector has been determined.

Keywords


Solar Concrete Collector, Pyranometer, Solar Intensity, Thermocouple, Temperature Indicator.

References