Refine your search
Collections
Co-Authors
Year
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z All
Oktar, Cebrail Hasimi
- Ellipsoidal Radiation Fields
Abstract Views :522 |
PDF Views:1
Authors
Affiliations
1 Department of History Science, History of Science Society, 440 Geddes Hall, University of Notre Dame, Notre Dame, IN 46556, IN
1 Department of History Science, History of Science Society, 440 Geddes Hall, University of Notre Dame, Notre Dame, IN 46556, IN
Source
Indian Journal of Applied Engineering Research, Vol 1, No 1 (2013), Pagination: 21-38Abstract
We put a radiation source P on an ellipsoidal surface. The design and performance characteristic of ellipsoidal radiation source, which is proposed for measurements of the total ellipsoidal radiation, is presented in this paper. An ellipsoidal radiation source is formed by an ellipsoidal cavity with high-reflectivity surface. This radiation field is based on ellipsoidal analysis, which allows generalizing the study of ellipsoidal radiation problems, is presented in this paper. From the analytic continuation of functions defined in a radiation field.Keywords
Ellipsoid Radiation Source/Point Radiation Source/Disk Radiation SourceReferences
- S. Yalcin, O. Gurler, G. Kaynak, O. Gundogdu,Calculation of total counting efficiency of a NaI(Tl) detector by hybrid Monte-Carlo method for point and disk sources J. Appl. Radiat. Isot . 65 (2007) 1179–1186
- Moens, L., De Donder, J., Lin, X., De Corte, F., De Wispelaere, A., Simonits, A., Hoste, J., 1981. Calculation of the absolute peak efficiency of gamma-ray detectors for different counting geometries. Nucl. Instrum. Methods 187 (2-3), 451–472.
- Birattari, C., Salomone, A., 1980. Efficiency evaluation of gamma-ray solidstate detectors. Nucl. Instrum. Methods 174 (3), 391–399.
- Cesana, A., Terrani, M., 1977. Gamma-ray activity determination in large volume samples with Ge–Li detector. Anal. Chem. 49 (8), 1156–1159.
- Perez-Andujar, A., Pibida, L., 2004. Performance of CdTe, HpGe and NaI(Tl) detectors for radioactivity measurements. Appl. Radiat. Isot. 60 (1), 41–47.
- Rieppo, R., Blomster, K., 1976. Calculated absolute photopeak efficiency values for 3_3 in NaI-detector with cylindrical source geometry. Int. J. Appl. Radiat. Isot. 27 (7), 365–367.
- Vegors Jr., S.H., Marsden, L.L., Heath, R.L., 1958. USAEC Report IDO- 16370.
- Wang, T.K., Chen, T.Y., Kang, L.J., 1993. A personal computer based program for HpGe detector absolute-peak-efficiency calculation and calibration. Appl. Radiat. Isot. 44 (8), 1147–1154.
- Zikovsky, L., Chah, B., 1988. A computer-program for calculating Ge(Li) detector counting efficiencies with large volume samples. Nucl. Instrum. Methods Phys. Res. A 263 (2–3), 483–486.
- Nakamura, T., 1972. Monte-Carlo calculation of efficiencies and response functions of NaI(Tl) crystals for thick disk gamma-ray sources and its application to Ge(Li) detectors. Nucl. Instrum. Methods 105, 77.
- H. Kang. E. Kim. and K. Kim. Anisotropic polarization tensors anddetermination of an anisotropic inclusion. SIAM J. Appl. Math.. 65 (2003). 1276-1291.
- H. Ammari. H. Kang and K. Kim. Polarization tensors and effective properties of anisotropic composite materials. J. Differ. Equat.. 215 (2005). 401-428.
- Hyeonbae Kang and Kyoungsun Kim.Anisotropic polarization tensor for ellipses and ellipsoids. J.Comp.Math. Vol.25. No.2. 2007. 157-168.
- Prank J. Bossen and Paul S. Heckbert. A pliant method for anisotropic mesh generation. In Proc. of 5th Intl. Meshing Roundtable, pages 63-74, 1996.