Measurement of Radon Concentration in Hookah Flavor


Affiliations
1 Physics Department, College of Sciences, Al-Muthana University, Iraq
2 Physics Department, College of Basic Education, Al-Muthana University, Iraq
 

In this work, we have measured the concentration of radon gas in samples of hookah flavor by using CR-39 nuclear track detector. To get the best results, these samples were dried by electric oven. Optical microscope (CM001 CYAN Scope) was used to count the number of tracks occurring on the detectors. The detectors were exposed to alpha particles emitted from the samples over a period of two months. NaOH - 6.25 N Solution was used to etch the detectors at 70 °C for 5 hours. The sealed-cup technique was used to measure the alpha particles emitted from the samples. The results obtained have proved the emission of Radon gas from hookah flavor, and shown different rates of concentration between 5.9 and 115 Bq/m3. The highest rate was in molasses Argelini / Melon honey dew flavor and the lowest rate in molasses Mazaya / Natural mint flavor.

Keywords

Radon Concentration, Hookah Flavor, Molasses, Sealed-Cup Technique, Nuclear Track Detector, CR-39.
User
Notifications
Font Size

Abstract Views: 154

PDF Views: 0




  • Measurement of Radon Concentration in Hookah Flavor

Abstract Views: 154  |  PDF Views: 0

Authors

Ali Nadhim Sabbar
Physics Department, College of Sciences, Al-Muthana University, Iraq
Hayder Salah Naeem
Physics Department, College of Basic Education, Al-Muthana University, Iraq

Abstract


In this work, we have measured the concentration of radon gas in samples of hookah flavor by using CR-39 nuclear track detector. To get the best results, these samples were dried by electric oven. Optical microscope (CM001 CYAN Scope) was used to count the number of tracks occurring on the detectors. The detectors were exposed to alpha particles emitted from the samples over a period of two months. NaOH - 6.25 N Solution was used to etch the detectors at 70 °C for 5 hours. The sealed-cup technique was used to measure the alpha particles emitted from the samples. The results obtained have proved the emission of Radon gas from hookah flavor, and shown different rates of concentration between 5.9 and 115 Bq/m3. The highest rate was in molasses Argelini / Melon honey dew flavor and the lowest rate in molasses Mazaya / Natural mint flavor.

Keywords


Radon Concentration, Hookah Flavor, Molasses, Sealed-Cup Technique, Nuclear Track Detector, CR-39.