Assessment and Evaluation of Radiology Darkroom in Benue State University Teaching Hospital and Federal Medical Centre Makurdi, Nigeria


Affiliations
1 Department of Physics, Benue State University, Makurdi, Benue State, Nigeria
2 Akawe Torkula College of Advanced and Professional Studies, Makurdi, Benue State, Nigeria
 

In every exposure, the primary goal of radiology is to obtain a high quality image with low radiation dose to patient. The research seeks to evaluate all the other factors that constitute high quality image with low radiation level in order that the ALARA (As Low As Reasonably Achievable) principle is maintained. In this work, the effect of safelight, white light, chemicals used for processing of radiology films and the time taken to process X-ray film in radiological units of some Hospitals in Benue State are determined and evaluated. The quality of the image in the darkroom is found to depend on how short the film is exposed to safelight. The processing chemicals and the temperature at which these films are processed and stored are also evaluated. The result obtained, show that the contrast level decreases as the exposure time increases as shown in the blue nature of the films exposed at longer time. Furthermore, the temperature of the processing solutions is seen to be very high when compared with ICRP and NCRP standards which indicates that the processing tanks at the two hospitals are not within the recommended standards and the standard humidity of (40-60%) are also not met.


Keywords

Dark Room, Safelight, X-Ray Film.
User
Notifications
Font Size

Abstract Views: 149

PDF Views: 1




  • Assessment and Evaluation of Radiology Darkroom in Benue State University Teaching Hospital and Federal Medical Centre Makurdi, Nigeria

Abstract Views: 149  |  PDF Views: 1

Authors

N. B. Akaagerger
Department of Physics, Benue State University, Makurdi, Benue State, Nigeria
E. H. Aligba
Akawe Torkula College of Advanced and Professional Studies, Makurdi, Benue State, Nigeria
A. I. Philip
Akawe Torkula College of Advanced and Professional Studies, Makurdi, Benue State, Nigeria

Abstract


In every exposure, the primary goal of radiology is to obtain a high quality image with low radiation dose to patient. The research seeks to evaluate all the other factors that constitute high quality image with low radiation level in order that the ALARA (As Low As Reasonably Achievable) principle is maintained. In this work, the effect of safelight, white light, chemicals used for processing of radiology films and the time taken to process X-ray film in radiological units of some Hospitals in Benue State are determined and evaluated. The quality of the image in the darkroom is found to depend on how short the film is exposed to safelight. The processing chemicals and the temperature at which these films are processed and stored are also evaluated. The result obtained, show that the contrast level decreases as the exposure time increases as shown in the blue nature of the films exposed at longer time. Furthermore, the temperature of the processing solutions is seen to be very high when compared with ICRP and NCRP standards which indicates that the processing tanks at the two hospitals are not within the recommended standards and the standard humidity of (40-60%) are also not met.


Keywords


Dark Room, Safelight, X-Ray Film.