Open Access Open Access  Restricted Access Subscription Access

An In-Vitro Study Comparing Shear-Peel Band Strength of Untreated and Sandblasted Orthodontic Bands Using Conventional Glass Lonomer Cements


Affiliations
1 Department of Dentistry, Assam Medical College and Hospital, Dibrugarh, Assam, India
2 Department of Orthodontics, Regional Dental College, Guwahati, Assam, India
 

Objectives: To compare the shear-peel band strength of untreated (non-sandblasted) and sandblasted orthodontic bands using two conventional glass ionomer cements-KetacTM-Cem Radiopaque (3M, ESPE) and GC Gold Label Type-1 (GC, Corporation). Methodology: 50 freshly extracted human mandibular third molars were selected and randomly assigned groups of 25 sample each for specific cements with and without sandblasting. Shear-peel band strength in megapascals were obtained by debanding the cemented bands for each group's specimen using an Instron Universal Testing Machine. Data was analyzed with ANOVA followed by a Tukey test. Results: An increase of 72.4% in the retentive strength was observed with sandblasted orthodontic bands cemented with KetacTMCem and about 76.2% of retentive strength with sandblasted one cemented with GC type-1 glass ionomer cement in comparison to untreated bands. Conclusion: Statistically significant differences were noted between non-sandblasted and sandblasted bands groups. The retentive force was increased to almost three quarter folds with sandblasted bands, irrespective of cement used.

Keywords

Orthodontic Bands, Glass Ionomer Cements, Shear Peel Strength, Sand-Blast.
User
Notifications
Font Size

  • Norris DS, Mclnnes Ledoux, Weinberg. Retention of orthodontic bands with new fluoride releasing cements. AJO 1986;89:206-211.
  • Mirzahi E. Glass Ionomer Cements in orthodontics an update. Am J Orthod Dentofacial Orthop 1988;93:505-507.
  • Stirrups DR A Comparative clinical trial of a Glass lonomer and a Zinc phosphate cement for securing orthodontic bands. British Journal of Orthodontics 1991;18:15-20.
  • Durning P, McCabe JF and Gordon PH. A laboratory investigation into cements used to retain orthodontic bands. British Journal of Orthodontics 1994;21:27-32.
  • Wood DP, Paleczny GJ, Johnson L. The effect of sandblasting on the retention of orthodontic bands. Angle Orthod 1996;66(3):207-214.
  • Miller S, Zernik J. Sandblasting of bands to increase bond strength. JCO 1996;4:217-222.
  • Seeholzer H, Dasch W. Banding with a Glass lonomer Cement JCO 1988;XXII(3):165-169.
  • Millet DT, McMable JF Bennett TG, Gordon PH. The effect of sandblasting on the retention of first molar orthodontic bands cemented with Glass lonomer Cement. BJO 1995;22:161-9.
  • Aggarwal Manish, Foley Timothy F and Douglas. A Comparison of Shear-Peel Band Strengths of 5 Orthodontic Cements. Angle Orthod 2000;70:308–316.
  • Hodges SJ, Gilthrope MS and Hunt NP. The effect of microetching on the retention of orthodontic molars bands: a clinical trial. European Journal of Orthodontics 2001;23:91–97.
  • Millett DT, Cummings A, Letters S, Roger E and Love J. Resinmodified glass ionomer, modified composite or conventional glass ionomer for band cementation? An in vitro evaluation. European Journal of Orthodontics 2003;25:609–614.

Abstract Views: 192

PDF Views: 58




  • An In-Vitro Study Comparing Shear-Peel Band Strength of Untreated and Sandblasted Orthodontic Bands Using Conventional Glass Lonomer Cements

Abstract Views: 192  |  PDF Views: 58

Authors

Md. Kalim Ullah
Department of Dentistry, Assam Medical College and Hospital, Dibrugarh, Assam, India
Mitali Bora
Department of Orthodontics, Regional Dental College, Guwahati, Assam, India

Abstract


Objectives: To compare the shear-peel band strength of untreated (non-sandblasted) and sandblasted orthodontic bands using two conventional glass ionomer cements-KetacTM-Cem Radiopaque (3M, ESPE) and GC Gold Label Type-1 (GC, Corporation). Methodology: 50 freshly extracted human mandibular third molars were selected and randomly assigned groups of 25 sample each for specific cements with and without sandblasting. Shear-peel band strength in megapascals were obtained by debanding the cemented bands for each group's specimen using an Instron Universal Testing Machine. Data was analyzed with ANOVA followed by a Tukey test. Results: An increase of 72.4% in the retentive strength was observed with sandblasted orthodontic bands cemented with KetacTMCem and about 76.2% of retentive strength with sandblasted one cemented with GC type-1 glass ionomer cement in comparison to untreated bands. Conclusion: Statistically significant differences were noted between non-sandblasted and sandblasted bands groups. The retentive force was increased to almost three quarter folds with sandblasted bands, irrespective of cement used.

Keywords


Orthodontic Bands, Glass Ionomer Cements, Shear Peel Strength, Sand-Blast.

References