Open Access Open Access  Restricted Access Subscription Access

To Determine the Functional Efficacy of LED Units in Various Clinical Offices


Affiliations
1 Department of Conservative Dentistry & Endodontics, Bhojia Dental College & Hospital, Himachal Pradesh, India
 

Aim: Light units used for polymerization of resin composites are subject to deterioration with age, and frequent maintenance is required to maintain optimal efficacy. The aim of this study was to examine the efficacy of LED units in private dental offices in Baddi (H.P) for polymerization of resin composites. Materials andMethods: Twenty dental officesmet all selection criteria and agreed to participate in the study.To measure light intensity, an analogue radiometer was used. The probe of each LED unit was placed and then measurements of light intensities were recorded for each light unit and the data was statistically analysed. Results: The light intensity of the individual units varied widely. The results revealed that there was error of 35% and a standard deviation of 155.76 among the intensities of various LED Units checked in the study. Conclusions: Light polymerization units in private dental offices displayed a wide range in light intensity, and many had below-recommended levels. A positive linear relationship was found between light intensity and photoactivation effectiveness. Dentists should regularly monitor the condition of light units and replace deteriorating parts.

Keywords

Composite, LED, Wavelength, Polymerisation.
User
Notifications
Font Size

Abstract Views: 203

PDF Views: 99




  • To Determine the Functional Efficacy of LED Units in Various Clinical Offices

Abstract Views: 203  |  PDF Views: 99

Authors

Kamal Nabhi
Department of Conservative Dentistry & Endodontics, Bhojia Dental College & Hospital, Himachal Pradesh, India
Ajay Chhabra
Department of Conservative Dentistry & Endodontics, Bhojia Dental College & Hospital, Himachal Pradesh, India
Varun Jindal
Department of Conservative Dentistry & Endodontics, Bhojia Dental College & Hospital, Himachal Pradesh, India
Damanpreet
Department of Conservative Dentistry & Endodontics, Bhojia Dental College & Hospital, Himachal Pradesh, India

Abstract


Aim: Light units used for polymerization of resin composites are subject to deterioration with age, and frequent maintenance is required to maintain optimal efficacy. The aim of this study was to examine the efficacy of LED units in private dental offices in Baddi (H.P) for polymerization of resin composites. Materials andMethods: Twenty dental officesmet all selection criteria and agreed to participate in the study.To measure light intensity, an analogue radiometer was used. The probe of each LED unit was placed and then measurements of light intensities were recorded for each light unit and the data was statistically analysed. Results: The light intensity of the individual units varied widely. The results revealed that there was error of 35% and a standard deviation of 155.76 among the intensities of various LED Units checked in the study. Conclusions: Light polymerization units in private dental offices displayed a wide range in light intensity, and many had below-recommended levels. A positive linear relationship was found between light intensity and photoactivation effectiveness. Dentists should regularly monitor the condition of light units and replace deteriorating parts.

Keywords


Composite, LED, Wavelength, Polymerisation.