Power Quality problems are emerging as most important issues for today's power system engineers. Major use of power electronics devices has increased the harmonics disturbances in power systems. These harmonics are basically due to presence of non-linear load in power system. These loads draw harmonic and reactive power components of current and voltage from main supply. Basically Current Harmonics are generated by these nonlinear loads due to nonlinear currents of load, for example drives of adjustable speed, static power supply, UPS etc. To reduce the effects of harmonics, voltage and current compensator is required. Among different types of compensators Shunt Active Power Filters (SAPF) has better harmonics compensation. This article includes the introduction of hysteresis control technique which was applied to compensate the current harmonics in power system.

Keywords

Harmonics, Shunt Active Power Filter, Hysteresis Current Control Technique.
User
Notifications
Font Size

  • Acha, E., Agelidis, V., Anaya, O., & Miller, T. J. E. (2001). Power electronic control in electrical systems. Elsevier.
  • Bose, B. K. (1990). An adaptive hysteresis-band current control technique of a voltage-fed PWM inverter for machine drive system. IEEE Transactions on industrial electronics, 37(5), 402-408.
  • Chandra, A., Singh, B., Singh, B. N., & Al-Haddad, K. (2000). An improved control algorithm of shunt active filter for voltage regulation, harmonic elimination, power-factor correction, and balancing of nonlinear loads. IEEE Transactions on Power Electronics, 15(3), 495-507.
  • da Silva, E. S., Martins, M. P., Coelho, E. A. A., de Freitas, L. C., Vieira, J. B., & Farias, V. J. (2002). Soft-single-switched boost PRC using UC3854 and special hysteresis current control technique. In Power Electronics Specialists Conference, 2002. pesc 02. 2002 IEEE 33rd Annual (Vol. 3, pp. 1369-1374). IEEE.
  • Jain, S. K., Agrawal, P., & Gupta, H. O. (2002). Fuzzy logic controlled shunt active power filter for power quality improvement. IEE Proceedings-Electric Power Applications, 149(5), 317-328.
  • Jin, C. (2013). Theory of nonlinear propagation of high harmonics generated in a gaseous medium. Springer Science & Business Media.

Abstract Views: 355

PDF Views: 218




  • Study on Current Harmonic's Mitigation Using Hysteresis Current Controller Technique

Abstract Views: 355  |  PDF Views: 218

Authors

Gopika Agarwal
Electrical and Electronics Engineering Dept., KIT, Rooma, Kanpur, U.P., India

Abstract


Power Quality problems are emerging as most important issues for today's power system engineers. Major use of power electronics devices has increased the harmonics disturbances in power systems. These harmonics are basically due to presence of non-linear load in power system. These loads draw harmonic and reactive power components of current and voltage from main supply. Basically Current Harmonics are generated by these nonlinear loads due to nonlinear currents of load, for example drives of adjustable speed, static power supply, UPS etc. To reduce the effects of harmonics, voltage and current compensator is required. Among different types of compensators Shunt Active Power Filters (SAPF) has better harmonics compensation. This article includes the introduction of hysteresis control technique which was applied to compensate the current harmonics in power system.

Keywords


Harmonics, Shunt Active Power Filter, Hysteresis Current Control Technique.

References