Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Novel Drug Selective Sensors for Simultaneous Potentiometric Determination of both Ciprofloxacin and Metronidazole in Pure form and Pharmaceutical Formulations


Affiliations
1 Department of Analytical and Food Chemistry, Aleppo University, Syrian Arab Republic
     

   Subscribe/Renew Journal


To investigate the ability of incorporating more than one ion pair in the same selective electrode's membrane, and so constructing an electrode sensitive to either Ciprofloxacin (CFX) or Metronidazole (MZL) according to the standard filling solution of the electrode, subsequently determine the two drugs CFX and MZL Simultaneously in their combined solutions, 3 PVC membrane drug selective sensors were constructed for CFX and MZL analysis intended. The electro active materials were CFX-Phosphotungstic Acid (CFX-PTA), MZL-Phosphotungstic Acid (MZL-PTA) and a composition of CFX-PTA+MZL-PTA. The characterization and analytical properties were determined, and the casting selective membranes of the selective electrodes were plasticized by di-n-butyl phthalate (DBP). Each of the assembled electrodes have internal reference Ag/AgCl electrode. Also, the gathered sensors have external reference Ag/AgCl electrode. The developed sensors showed near Nernstian response for ion pair percentages of 6%, and 7% for CFX-PTA, MZL-PTA, respectively. The electrodes demonstrated a rapid responses of 10-16 sec for a period of 13-15 days, with no changes that have meaningful results in the electrodes parameters. The suggested sensors have a measurement pH ranges 2.0-6.0 for CFX, and 2.0-5.0 for MZL without using any buffer. The sensors were used as indicator electrodes for direct determination of CFX and MZL in pharmaceutical preparations with mean relative standard deviation less than 2% that indicating good precision, as well as in pure form solutions with average recovery of 99.96%, 99.93% and 99.83% (CFX) or 99.88% (MZL) and a mean relative standard deviation of 0.05%, 0.18% and 0.06% (CFX) or 0.18% (MZL)% at 1 mM (367.8 μg/mL CFX, or 171.2 μg/mL MZL) for CFX-PTA, MZL-PTA, and CFX-PTA+MZL-PTA sensors respectively.

Keywords

Ion Selective Electrode, Novel Drug selective membrane, Ciprofloxacin, Metronidazole, Simultaneous Potentiometric Determination.
Subscription Login to verify subscription
User
Notifications
Font Size


  • National Center for Biotechnology Information. Pub Chem Compound Database; CID=62999, https://pubchem.ncbi.nlm.nih.gov/compound/62999 (accessed Dec 22, 2018).
  • E. C. Johannsen, M. S. Sabatine, Pharm Cards: Review Cards for Medical Students, Fourth Edition (Wolters Kluwer, Lippincott Williams & Wilkins, 2010).
  • National Center for Biotechnology Information. Pub Chem Compound Database; CID=4173, https://pubchem.ncbi.nlm.nih.gov/compound/4173 (accessed Dec 22, 2018).
  • G. Kawas, M. Marouf, O. Mansour, A.A. Sakur, Analytical Methods of Ciprofloxacin and its Combinations Review, Research Journal of Pharmacy and Technology, 2018, 11(5): 2139-2148.
  • E.C.L. Cazedey, H.R.N. Salgado, Spectrophotometric Determination of Ciprofloxacin Hydrochloride in Ophthalmic Solution, Advances in Analytical Chemistry, 2012; 2(6): 74-79.
  • R. Kharat, S. Jadhav, D. Tamboli, A. Tamboli, Estimation of Ciprofloxacin Hydrochloride in Bulk and Formulation by Derivative UV-Spectrophotometric Methods, International Journal of Advances in Scientific Research, 2015,1(03): 137-144.
  • R. Kazan, H. Mandil, A.A. Sakur, Spectrophotometric Determination of Ciprofloxacin in Pharmaceutical Formalations Using Bromocresol Green, R. J. of Aleppo Univ. Science Series, 2008, vol 62: 143-160.
  • R. Kazan, H. Mandil, A.A. Sakur, Spectroflourimetric Determination of Ciprofloxacin and Norfloxacin, Arab Journal of pharmaceutical Sciences, 2009, vol 4: 93-101.
  • X. Li, Q. Cao, F. Wang, Determination of ciprofloxacin hydrochloride in pharmaceutical preparation and biological fluid by Rayleigh light scattering technique, Wuhan University Journal of Natural Sciences, 2009, Volume 14, Issue 1, pp 70–74.
  • Xu-ZhiZhang et al., Simple and cost-effective determination of ciprofloxacin hydrochloride by electrical micro-titration, Chinese Chemical Letters, 2017; Volume 28, Issue 7: 1406-1412.
  • Michalska et al., Determination of ciprofloxacin and its impurities by capillary zone electrophoresis, Journal of Chromatography A, 2004, Volume 1051, Issues 1–2, Pages 267-272.
  • H. Mandil, A.A. Sakur, B. Nasser, Potentiometric determination of gatifloxacin & ciprofloxacin in pharmaceutical formulations, International Journal of Pharmacy and Pharmaceutical Sciences, 2012, 4(4): 537-542.
  • E. Ezzeldin, TM El-Nahhas, New Analytical Method for the Determination of Metronidazole in Human Plasma: Application to Bioequivalence Study, Tropical Journal of Pharmaceutical Research, 2012, 11 (5): 799-805.
  • K. Siddappa, M. Mallikarjun, P.T. Reddy, M. Tambe, Spectrophotometric determination of metronidazole through Schiff’s base system using vanillin and PDAB reagents in pharmaceutical preparations, ECLETICA Quimica, 2008, 33(4): 41-46.
  • P. Thulasamma, P. Venkateswarlu, Spectrophotometric Method for the Determination of Metronidazole in Pharmaceutical Pure and Dosage Forms, RASĀYAN Journal of Chemistry, 2009, Vol.2(4): 865-868.
  • YILMAZ et al., Electroanalytical determination of metronidazole in tablet dosage form, Journal of the Serbian Chemical Society, 2013, 78 (2): 295–302.
  • R. Piech, J. Smajdor, B.P. Bator, M. Rumin, Fast and sensitive metronidazole determination by means of voltammetry on renewable amalgam silver-based electrode without the preconcentration step, Journal of the Serbian Chemical Society, 2017, 82 (7–8): 879–890.
  • A. Ensafi, P.N. Esfahani, B. Rezaei, Metronidazole determination with an extremely sensitive and selective electrochemical sensor based on graphene nanoplatelets and molecularly imprinted polymers on graphene quantum dots, Sensors and Actuators B: Chemical, 2018, Vol. 270: 192-199.
  • Y. Nikodimos, M. Amare, Electrochemical Determination of Metronidazole in Tablet Samples Using Carbon Paste Electrode, Journal of Analytical Methods in Chemistry, 2016, vol. 2016, Article ID 3612943, 7 pages.
  • El-bagary et al., Simultaneous determination of ciprofloxacin hydrochloride and metronidazole in spiked human plasma by ultra-performance liquid chromatography-tandem mass spectroscopy, Journal of Applied Pharmaceutical Science, 2016, 6(3): 041-047.
  • E.F. Elkady, M.A. Mahrouse, Reversed-Phase Ion-Pair HPLC and TLC-Densitometric Methods for the Simultaneous Determination of Ciprofloxacin Hydrochloride and Metronidazole in Tablets, Chromatographia, 2011; Volume 73, Issue 3–4, pp 297–305.
  • M.A. Mahrouse, E.F. Elkady, Validated Spectrophotometric Methods for the Simultaneous Determination of Ciprofloxacin Hydrochloride and Metronidazole in Tablets, Chemical and Pharmaceutical Bulletin, 2011, 59(12): 1485-1493.
  • A.A. Sakur, S. Bassmajei, H.A. Dabbeet, Novel Moxifloxacin Ion Selective Electrodes for Potentiometric Determination of Moxifloxacin in Pure Form and Pharmaceutical Formulations, International Journal of Academic Scientific Research, 2015; 3(4): 66-75.
  • M. Haroun, D. Nashed, A.A. Sakur, New electrochemical methods for the determination of Prasugrel using drug selective membranes, International Journal of Ac ademic Scientific Research, 2017, 5(3): 30-36.
  • O. Mansour, D. Nashed, A.A. Sakur, Determination of Clopidogrelbisulphate using Drug Selective Membranes, Research Journal of Pharmacy and Technology, 2018, 11(5): 2017-2021.
  • A.A. Sakur, D. Nashed, M. Haroun, I. Noureldin, Determination of Prasugrel Hydrochloride in Bulk and Pharmaceutical Formulation Using New Ion Selective Electrodes, Research Journal of Pharmacy and Technology, 2018, 11(2): 631-636.
  • J.E. Reynolds, M. Josowicz, R.B. Vegh, K.M. Solntsev, Spectral and Redox Properties of the GFP Synthetic Chromophores as a Function of pH in buffered media, Electronic Supplementary Material (ESI) for Chemical Communications (The Royal Society of Chemistry, 2013).
  • G.J. Moody, N.S. Nassory, J.D.R. Thomas, Some observations on the selectivity assessment of calcium ion-selective electrodes, Hung. Sci. Instrum., 41, 1977, 23-26.
  • G.J. Moody, N.S. Nassory, J.D.R. Thomas, Calcium ion-selective electrodes based on calcium bis[di(p-1,1,3,3- tetramethylibuthyl phenyl)- phosphate] sensor and trialkyl phosphate mediators, Analyst (London), 103(1), 1978, 68-71.
  • R.P. Buck, E. Lindner, Recommendations for nomenclature of ion-selective electrodes, Pure and Applied Chemistry: Analytical Chemistry Division, 1194, 66(12): 2527-2536.
  • Y. Umezawa, P. Bühlmann, K. Umezawa, K. Tohda, S. Amemiya, Potentiometric selectivity coefficients of ion-selective electrodes part I. inorganic cations (technical report). Pure and Applied Chemistry: Analytical Chemistry Division, 2000, 72(10): 1851-2082.
  • J.D.R. Thomas, Devices for ion-sensing and pX measurement, Pure and Applied Chemistry: Analytical Chemistry Division, 2001, 73(1): 31-38.
  • MASLARSKA et al., HPLC Assay Of Model Tablet Formulations Containing Metronidazole And Ciprofloxacin, International Journal of Pharmacy and Pharmaceutical Sciences, 2016, 8(5): 306-310.
  • R.P. Buck, E. Lindner, Recommendations for nomenclature of ion-selective electrodes, Pure and Applied Chemistry: Analytical Chemistry Division, 1994; 66(12): 2527-2536.
  • M.S. Bassmajei, Determination of Some Pharmaceutical Compounds by New Plastic Membrane Ion-Selective Electrodes. doctoral diss., University of Aleppo, Aleppo, Syria, 2005.
  • H. Mandil, A.A. Sakur, B. NASSER, New ion selective electrode for potentiometric determination of gatifloxacin in pure form and pharmaceutical formulations, Int. J Pharm Pharm Sci, 2013; 5(2): 423-428.
  • P.C. Meier, R.E. Zünd, Statistical Methods in Analytical Chemistry, 2nd Edn., in J.D. Winefordner (Ser. Edr.), Chemical Analysis: A Series of Monographs on Analytical Chemistry and Its Applications, 153 (New York, Wiley-Interscience publication, 2000): 48-55 and 69-72.

Abstract Views: 332

PDF Views: 0




  • Novel Drug Selective Sensors for Simultaneous Potentiometric Determination of both Ciprofloxacin and Metronidazole in Pure form and Pharmaceutical Formulations

Abstract Views: 332  |  PDF Views: 0

Authors

Amir Alhaj Sakur
Department of Analytical and Food Chemistry, Aleppo University, Syrian Arab Republic
Hashem A. Dabbeet
Department of Analytical and Food Chemistry, Aleppo University, Syrian Arab Republic
Imad Noureldin
Department of Analytical and Food Chemistry, Aleppo University, Syrian Arab Republic

Abstract


To investigate the ability of incorporating more than one ion pair in the same selective electrode's membrane, and so constructing an electrode sensitive to either Ciprofloxacin (CFX) or Metronidazole (MZL) according to the standard filling solution of the electrode, subsequently determine the two drugs CFX and MZL Simultaneously in their combined solutions, 3 PVC membrane drug selective sensors were constructed for CFX and MZL analysis intended. The electro active materials were CFX-Phosphotungstic Acid (CFX-PTA), MZL-Phosphotungstic Acid (MZL-PTA) and a composition of CFX-PTA+MZL-PTA. The characterization and analytical properties were determined, and the casting selective membranes of the selective electrodes were plasticized by di-n-butyl phthalate (DBP). Each of the assembled electrodes have internal reference Ag/AgCl electrode. Also, the gathered sensors have external reference Ag/AgCl electrode. The developed sensors showed near Nernstian response for ion pair percentages of 6%, and 7% for CFX-PTA, MZL-PTA, respectively. The electrodes demonstrated a rapid responses of 10-16 sec for a period of 13-15 days, with no changes that have meaningful results in the electrodes parameters. The suggested sensors have a measurement pH ranges 2.0-6.0 for CFX, and 2.0-5.0 for MZL without using any buffer. The sensors were used as indicator electrodes for direct determination of CFX and MZL in pharmaceutical preparations with mean relative standard deviation less than 2% that indicating good precision, as well as in pure form solutions with average recovery of 99.96%, 99.93% and 99.83% (CFX) or 99.88% (MZL) and a mean relative standard deviation of 0.05%, 0.18% and 0.06% (CFX) or 0.18% (MZL)% at 1 mM (367.8 μg/mL CFX, or 171.2 μg/mL MZL) for CFX-PTA, MZL-PTA, and CFX-PTA+MZL-PTA sensors respectively.

Keywords


Ion Selective Electrode, Novel Drug selective membrane, Ciprofloxacin, Metronidazole, Simultaneous Potentiometric Determination.

References