Method to Reduce the False-Positive Rate of Loss of Resistance in the Cervical Epidural Region


Affiliations
1 Department of Anesthesiology and Pain Medicine, Catholic Kwandong University of Korea College of Medicine, International St. Mary’s Hospital, Incheon,, Korea, Republic of
2 Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43 Gil, Songpa-gu, Seoul 05505, Korea, Republic of
 

Background: The cervical epidural space can be detected by the loss of resistance (LOR) technique which is commonly performed using air. However, this technique using air has been associated with a high false-positive LOR rate during cervical interlaminar epidural steroid injections (CIESIs). Objective: We investigated whether the detection of LOR with contrast medium might reduce the false-positive LOR rate on the first attempt. Methods: We obtained data retrospectively. A total of 79 patients were divided into two groups according to the LOR technique. Groups 1 and 2 patients underwent CIESI with the LOR technique using air or contrast medium. During the procedure, the injection technique (median or paramedian approach), final depth, LOR technique (air or contrast), total number of LOR attempts, and any side effects were recorded. Results: The mean values for the total number of LOR attempts were 1.38 ± 0.65 (Group 1) and 1.07 ± 0.25 (Group 2). The false-positive rate on the first attempt was 29.4% and 6.6% in Groups 1 and 2, respectively (P = 0.012). Conclusions: The use of contrast medium for LOR technique is associated with a lower rate of false-positivity compared with the use of air.
User
Notifications
Font Size

Abstract Views: 78

PDF Views: 0




  • Method to Reduce the False-Positive Rate of Loss of Resistance in the Cervical Epidural Region

Abstract Views: 78  |  PDF Views: 0

Authors

Young Uk Kim
Department of Anesthesiology and Pain Medicine, Catholic Kwandong University of Korea College of Medicine, International St. Mary’s Hospital, Incheon,, Korea, Republic of
Doohwan Kim
Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43 Gil, Songpa-gu, Seoul 05505, Korea, Republic of
Jun Young Park
Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43 Gil, Songpa-gu, Seoul 05505, Korea, Republic of
Jae-Hyung Choi
Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43 Gil, Songpa-gu, Seoul 05505, Korea, Republic of
Ji Hyun Kim
Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43 Gil, Songpa-gu, Seoul 05505, Korea, Republic of
Heon-Yong Bae
Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43 Gil, Songpa-gu, Seoul 05505, Korea, Republic of
Eun-Young Joo
Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43 Gil, Songpa-gu, Seoul 05505, Korea, Republic of
Jeong Hun Suh
Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43 Gil, Songpa-gu, Seoul 05505, Korea, Republic of

Abstract


Background: The cervical epidural space can be detected by the loss of resistance (LOR) technique which is commonly performed using air. However, this technique using air has been associated with a high false-positive LOR rate during cervical interlaminar epidural steroid injections (CIESIs). Objective: We investigated whether the detection of LOR with contrast medium might reduce the false-positive LOR rate on the first attempt. Methods: We obtained data retrospectively. A total of 79 patients were divided into two groups according to the LOR technique. Groups 1 and 2 patients underwent CIESI with the LOR technique using air or contrast medium. During the procedure, the injection technique (median or paramedian approach), final depth, LOR technique (air or contrast), total number of LOR attempts, and any side effects were recorded. Results: The mean values for the total number of LOR attempts were 1.38 ± 0.65 (Group 1) and 1.07 ± 0.25 (Group 2). The false-positive rate on the first attempt was 29.4% and 6.6% in Groups 1 and 2, respectively (P = 0.012). Conclusions: The use of contrast medium for LOR technique is associated with a lower rate of false-positivity compared with the use of air.