Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Mulidisciplinary Vm - Weight Distribution Analysis System: A Diagnostic and Evaluative Tool for Altered Weight Distribution


Affiliations
1 Department of Physical Medicine and Rehab, S.M. Medical University, (Formerly King George Medical University) Lucknow, U.P, India
2 Department of Physical Medicine and Rehab, S.M. Medical University, (Formerly King George Medical University) Lucknow, U.P., India
3 Dept. of Orthopaedic Surgery, C.S.M. Medical University, (Formerly King George Medical University) Lucknow, U.P.,, India
     

   Subscribe/Renew Journal


Weight distribution pattern is a vital biomechanical parameter to evaluate knee joint changes and its functional correlates in knee osteoarthritis. VM - Weight Distribution Analysis System is a uniquely designed foot plate consisting of transducers (load cells), the interface and, digital display unit to measure static load distribution as well as variation in load distribution in different functional positions to quantify the variability in weight distribution and identify the biomechanical factors / attributes responsible for altered weight distribution. Understanding of this altered distribution is of utmost importance in the treatment of arthritic knee leading to compromised lifestyle and pain. The treatment process in knee osteoarthritis includes selection and prescription of: appropriate knee orthosis, shoe modification and exercise regime to maximize the efficiency of a person within the environmental context. The knowledge of this altered weight distribution in knee osteoarthritis over different areas of feet guides the process of designing, selection and prescription of orthosis as well as treatment implementation. This VM - Weight Distribution Analysis System provides the knowledge of altered load distribution over different regions of feet simultaneously and guide the clinical decision making process.

Keywords

VM-weight Distribution Analysis System; Knee Osteoarthritis; Altered Weight Distribution
Subscription Login to verify subscription
User
Notifications
Font Size


  • Axel Hillmanna, Dieter Rosenbaumab, Winfried Winkelmanna, Plantar and dorsal foot loading measurements in patients after rotationplast, Clinical Biomechanics:2000:15(5):359-64.
  • Bennett PJ, Duplock LR. Pressure distribution beneath the human foot, J Am Podiatr Med Assoc, 1993:83(12):674-8.
  • Cavanagh P R, Rodgers M M, Liboshi A. Pressure distribution under symptom free feet during barefoot standing. Foot Ankle, 1987:7(5):262-76.
  • Luger EJ, Nissan M, karpf A, Steinberg EL, Dekel S. Patterns of weight distribution under the metatarsal heads, J Bone Joint Surg Br, 1999:81:199-202.
  • Mao De Wei, jing Xian Li, Yulian Hong. Plantar pressure distribution during tai Chi exercise, Arch Phys Med Rehabil, 2006:87(6):814-20.
  • Rai D V, Aggarwal L M. The study of plantar pressure distribution in normal and pathological foot, Pol J Med Phys Eng 2006:12(1):25-34.
  • Sammarco G James, Hockenbury Ross Todd, Biomechanics of the foot and ankle. In: Nordin M, Frankel VH, eds. Basic Biomechanics of the Musculoskeletal system. Baltimore: 3rd ed. Lippincott Williams & Wilkins, 2001; p. 222-55.

Abstract Views: 232

PDF Views: 0




  • Mulidisciplinary Vm - Weight Distribution Analysis System: A Diagnostic and Evaluative Tool for Altered Weight Distribution

Abstract Views: 232  |  PDF Views: 0

Authors

Vijay Batra
Department of Physical Medicine and Rehab, S.M. Medical University, (Formerly King George Medical University) Lucknow, U.P, India
V. P. Sharma
Department of Physical Medicine and Rehab, S.M. Medical University, (Formerly King George Medical University) Lucknow, U.P, India
Meenakshi Batra
Department of Physical Medicine and Rehab, S.M. Medical University, (Formerly King George Medical University) Lucknow, U.P., India
Vineet Sharma
Dept. of Orthopaedic Surgery, C.S.M. Medical University, (Formerly King George Medical University) Lucknow, U.P.,, India

Abstract


Weight distribution pattern is a vital biomechanical parameter to evaluate knee joint changes and its functional correlates in knee osteoarthritis. VM - Weight Distribution Analysis System is a uniquely designed foot plate consisting of transducers (load cells), the interface and, digital display unit to measure static load distribution as well as variation in load distribution in different functional positions to quantify the variability in weight distribution and identify the biomechanical factors / attributes responsible for altered weight distribution. Understanding of this altered distribution is of utmost importance in the treatment of arthritic knee leading to compromised lifestyle and pain. The treatment process in knee osteoarthritis includes selection and prescription of: appropriate knee orthosis, shoe modification and exercise regime to maximize the efficiency of a person within the environmental context. The knowledge of this altered weight distribution in knee osteoarthritis over different areas of feet guides the process of designing, selection and prescription of orthosis as well as treatment implementation. This VM - Weight Distribution Analysis System provides the knowledge of altered load distribution over different regions of feet simultaneously and guide the clinical decision making process.

Keywords


VM-weight Distribution Analysis System; Knee Osteoarthritis; Altered Weight Distribution

References