A laboratory scale model of composite radial filter was designed, fabricated and tested for recharging aquifer with canal water. Charcoal (C), coarse sand (CS) and gravel (G) filter materials were placed in annular rings of developed radial filter in different combination of thickness, viz. 1 : 1 : 1, 1 : 1 : 2, 1 : 2 : 2 and 1 : 2 : 1 for four treatments T1, T2, T3 and T4 respectively. Flow equation for discharge through composite radial filter was developed and verified through experiments. The design depth of the filter for given discharge was also obtained. Sodium hypochlorite solution was injected through chlorination unit at the outlet of the radial filter to remove the bacteriological contamination of filtered water. The performance of composite radial filter was evaluated by analyzing canal water before and after filtration. Water quality parameters of filtered water were found to be within permissible limit at low flow rate (0.3 lps). The water quality parameters of filtered water from treatment T3 with thickness of 10, 20 and 20 cm for C, CS and G respectively was found to be comparatively better than other three treatments (T1, T2 and T4). The composite radial filter consists of C, CS and G filter media having thickness in ratio of 1 : 2 : 2 was found to be the best for recharging groundwater aquifer with canal water.

Keywords

Aquifer, Artificial Recharge, Canal Water, Composite Radial, Filter.
User
Notifications
Font Size

  • Rodell, M., Velicogna, I. and Famiglietti, J. S., Satellite-based estimates of groundwater depletion in India. Nature, 2009. 460(7258), 999–1002.
  • Kamra, S. K. and Sharma, D. K., Groundwater recharge structures for small farmers in alluvial regions. In Third Ground Water Congress, Central Ground Water Board, Ministry of Water Resources, Government of India, 2011, 22–23, pp. 168–174.
  • Kumar, S., Kamra, S. K., Yadav, R. K. and Sharma, J. P., Evaluation of sand-based storm water filtration system for groundwater recharge wells. Curr. Sci., 2012, 103(4), 395–404.
  • Ramachandrappa, B. K., Thimmegowda, M. N., Anitha, M., Sathish, A., Devaraja. K. and Jagadeesh, B. N., Studies on borewell recharge through filter bed using runoff water in eastern dry zone of Karnataka. Indian J. Dryland Agric. Res. Dev., 2016, 30(2), 44–49.
  • Verma, O. P., Khanan, B. and Shukla, S., Determination of physicochemical characteristics of four canals of Allahabad region and its suitability for irrigation. Adv. Appl. Sci. Res., 2012, 3, 1531– 1537.
  • Matta, G., Pandey, R. R. and Saini, K. K., Assessment of pollution on water quality and phytoplankton diversity in canal system of river Ganga. World Res. J. Pharmaceut. Res., 2015, 4, 889– 908.
  • Channa, Ali S, Jakhrani, A. Q., Mukwana, K. C. and Jakhrani, S. H., Analysis of physico-chemical and biological quality parameters of Phuleli canal water and wastewater adjacent to Hyderabad city. J. Eng. Sci. Technol., 2015, 14, 26–33.
  • Zhanga, X., Zhaoa, X., Zhanga, M. and Qian-yuan, W., Safety evaluation of an artificial groundwater recharge system for reclaimed water reuse based on bioassays. Curr. Sci., 2011, 10(5), 657–661.
  • McCormick, R. L., Filter pack installation and redevelopment techniques for shallow recharge shafts. Ground Water, 2017, 12(5), 400–405.
  • Czarnecki, J. B., Artifical recharge system. US Geol. Surv., 2012, 13(5), 891–893.
  • Anon., Annual report of AICRP – Groundwater utilization through tubewells and pumps. Artificial recharge studies. Department of Soil Water Eng. PAU, Ludhiana, 1995.
  • Kandra, H. S., Deletic, A. and McCarthy, D., Assessment of impact of filter design variables on clogging in storm water filters. Water Res. Manage., 2014, 28(1), 1873–1885.
  • Pendker, M. S., Choulwar, S. B., Rao, C. S., Chary, G. R. and Baviskar, V. S., Design, development and evaluation of artificial well recharging system for groundwater enhancement. Indian J. Dryland Agric. Res. Dev., 2014, 29(2), 17–22.
  • Kambale, J. B., Sarangi, A., Singh, D. K. and Singh, A. K., Performance evaluation of filtration unit of groundwater recharge shaft: laboratory study. Curr. Sci., 2009, 96, 471–474.
  • Krishna, K. S. and Jain, P., Performance evaluation of filtration system for groundwater recharging well in the presence of medium sand-mixed storm water. World Acad. Sci., 2015, 9(3), 224–227.

Abstract Views: 256

PDF Views: 87




  • Development of Composite Radial Filter for Recharging Aquifers with Canal Water

Abstract Views: 256  |  PDF Views: 87

Authors

Gaurav
Department of Soil and Water Engineering,Punjab Agricultural University, Ludhiana 141 027, India
J. P. Singh
Department of Soil and Water Engineering,Punjab Agricultural University, Ludhiana 141 027, India
P. P. Sahota
Department of Microbiology, Punjab Agricultural University, Ludhiana 141 027, India
K. Singh
Department of Soil Science, Punjab Agricultural University, Ludhiana 141 027, India

Abstract


A laboratory scale model of composite radial filter was designed, fabricated and tested for recharging aquifer with canal water. Charcoal (C), coarse sand (CS) and gravel (G) filter materials were placed in annular rings of developed radial filter in different combination of thickness, viz. 1 : 1 : 1, 1 : 1 : 2, 1 : 2 : 2 and 1 : 2 : 1 for four treatments T1, T2, T3 and T4 respectively. Flow equation for discharge through composite radial filter was developed and verified through experiments. The design depth of the filter for given discharge was also obtained. Sodium hypochlorite solution was injected through chlorination unit at the outlet of the radial filter to remove the bacteriological contamination of filtered water. The performance of composite radial filter was evaluated by analyzing canal water before and after filtration. Water quality parameters of filtered water were found to be within permissible limit at low flow rate (0.3 lps). The water quality parameters of filtered water from treatment T3 with thickness of 10, 20 and 20 cm for C, CS and G respectively was found to be comparatively better than other three treatments (T1, T2 and T4). The composite radial filter consists of C, CS and G filter media having thickness in ratio of 1 : 2 : 2 was found to be the best for recharging groundwater aquifer with canal water.