Open Access Open Access  Restricted Access Subscription Access

Foetal Movement Detection and Characterization Based on Force Sensing


Affiliations
1 Clinical Science Department, Faculty of Biosciences and Medical Engineering, Universiti Teknologi Malaysia, Skudai, Johor, Malaysia
 

This study presents a detection system for foetal movement classification based on the magnitude of force exerted on a pregnant woman’s abdominal wall. Despite the effectiveness of ultrasound method in foetal monitoring, the characterization of movement depends on an expert’s skill. A detection system was developed by incorporating force-sensitive resistor array into a wearable belt for pregnant women. The system characterized hand, leg and trunk movement with accuracy ranging from 75% to 93% with an accuracy of 98% on single movement detections compared to accelerometer performance. The system is thus a promising technique for low cost foetal movement detection.
User
Notifications
Font Size

  • Hantoushzadeh, S., Sheikh, M., Shariat, M. and Farahani, Z., J. Mater. – Fetal Neonatal Med., 2015, 28(6), 713–717.
  • de Vries, J. I. P., Visser, G. H. A. and Prechtl, H. F. R., Early Hum. Dev., 1982, 7(4), 301–322.
  • Lai, J., Nowlan, N. C., Vaidyanathan, R., Shaw, C. J. and Lees, C. C., Acta Obstet. Gynecol. Scand., 2016, 95(9), 968–975.
  • Nishihara, K., Horiuchi, S., Eto, H. and Honda, M., Early Hum. Dev., 2008, 84(9), 595–603.
  • Schmidt, W., Kubli, F., Cseh, I. and Kara, K., J. Perinat. Med., 1984, 12(6), 313–318.
  • Mesbah, M., Khlif, M. S., East, C., Smeathers, J., Colditz, P. and Boashash, B., Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, 2011, pp. 7877–7880.
  • Goovaerts, H. G., Cohen, D., Dripps, J. H., Mantel, R., Mooney, P., Jongsma, H. W. and van Geijn, H. P., J. Biomed. Eng., 1991, 13(6), 495–499.
  • Liu, T., Inoue, Y. and Shibata, K., Sensors (Basel, Switzerland), 2010, 10(11), 10240–10255.
  • Kumar, N., Piccin, O., Meylheuc, L., Barbé, L. and Bayle, B., Design, development and preliminary assessment of a force sensor for robotized medical applications. IEEE/ASME International Conference on Advanced Intelligent Mechatronics, Besacon, 2014, pp. 1368–1374.
  • Verbruggen, S. W., Loo, J. H. W., Hayat, T. T. A., Hajnal, J. V., Rutherford, M. A., Phillips, A. T. M. and Nowlan, N. C., Biomech. Model. Mechanobiol., 2016, 15, 995–1004.
  • Hollinger, A. and Wanderley, M. M., Proceedings of International Conference on New Interfaces for Musical Expression, 2006.
  • Khlif, M. S. H., Boashash, B., Layeghy, S., Ben-Jabeur, T., Colditz, P. B. and East, C., 11th International Conference on Information Science, Signal Processing and their Applications, ISSPA, 2012, pp. 71–76.
  • Layeghy, S., Azemi, G., Colditz, P. and Boashash, B., Proceedings 8th International Conference on Signal Processing and Communication Systems, ICSPCS, 2014.
  • Ryo, E. and Kamata, H., J. Matern. – Fetal Neonatal Med., 2012, 25(12), 2629–2632.

Abstract Views: 247

PDF Views: 67




  • Foetal Movement Detection and Characterization Based on Force Sensing

Abstract Views: 247  |  PDF Views: 67

Authors

Rania Hussien Al-Ashwal
Clinical Science Department, Faculty of Biosciences and Medical Engineering, Universiti Teknologi Malaysia, Skudai, Johor, Malaysia
Amirul Ridhwan bin Sazali
Clinical Science Department, Faculty of Biosciences and Medical Engineering, Universiti Teknologi Malaysia, Skudai, Johor, Malaysia

Abstract


This study presents a detection system for foetal movement classification based on the magnitude of force exerted on a pregnant woman’s abdominal wall. Despite the effectiveness of ultrasound method in foetal monitoring, the characterization of movement depends on an expert’s skill. A detection system was developed by incorporating force-sensitive resistor array into a wearable belt for pregnant women. The system characterized hand, leg and trunk movement with accuracy ranging from 75% to 93% with an accuracy of 98% on single movement detections compared to accelerometer performance. The system is thus a promising technique for low cost foetal movement detection.

References





DOI: https://doi.org/10.18520/cs%2Fv115%2Fi4%2F629-632