Open Access Open Access  Restricted Access Subscription Access

Indigenous Development of a Millikelvin Refrigerator at VECC, Kolkata


Affiliations
1 Variable Energy Cyclotron Centre, 1/AF, Bidhan Nagar, Kolkata 700 064, India
 

Technologies related to production of millikelvin temperature have been developed and tested in the laboratory. All the critical components were assembled to make a complete dilution refrigerator. The refrigerator was successfully run and commissioned in VECC. The system involves several advanced cryogenic concepts especially the capillary impedance and heat exchanger. A temperature to the tune of 50 mK has been achieved. This is the first development of its kind in India, and likely to usher a new wave in the research arena of advanced cryogenics.

Keywords

Evaporator, Mixing Chamber, Millikelvin, 3He–4He Mixture.
User
Notifications
Font Size

Abstract Views: 192

PDF Views: 73




  • Indigenous Development of a Millikelvin Refrigerator at VECC, Kolkata

Abstract Views: 192  |  PDF Views: 73

Authors

Nisith Kr. Das
Variable Energy Cyclotron Centre, 1/AF, Bidhan Nagar, Kolkata 700 064, India
Jedidiah Pradhan
Variable Energy Cyclotron Centre, 1/AF, Bidhan Nagar, Kolkata 700 064, India
Bidhan Ch. Mondal
Variable Energy Cyclotron Centre, 1/AF, Bidhan Nagar, Kolkata 700 064, India
Anindya Roy
Variable Energy Cyclotron Centre, 1/AF, Bidhan Nagar, Kolkata 700 064, India
Z. A. Naser
Variable Energy Cyclotron Centre, 1/AF, Bidhan Nagar, Kolkata 700 064, India
Pradeep Kumar
Variable Energy Cyclotron Centre, 1/AF, Bidhan Nagar, Kolkata 700 064, India

Abstract


Technologies related to production of millikelvin temperature have been developed and tested in the laboratory. All the critical components were assembled to make a complete dilution refrigerator. The refrigerator was successfully run and commissioned in VECC. The system involves several advanced cryogenic concepts especially the capillary impedance and heat exchanger. A temperature to the tune of 50 mK has been achieved. This is the first development of its kind in India, and likely to usher a new wave in the research arena of advanced cryogenics.

Keywords


Evaporator, Mixing Chamber, Millikelvin, 3He–4He Mixture.



DOI: https://doi.org/10.18520/cs%2Fv112%2Fi05%2F1023-1028